General information
|
|
|
|
Product type designation
|
SIMATIC HMI KP8 PN
|
SIMATIC HMI KP8F PN
|
SIMATIC HMI KP32F PN
|
Control elements
|
|
|
|
With parameterizable keys
|
Yes
|
Yes
|
Yes
|
Keyboard fonts
|
|
|
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
|
|
|
|
8
|
8
|
32
|
Expansions for operator control of the process
|
|
|
|
|
8; Adjustable brightness
|
8; Adjustable brightness
|
8; Adjustable brightness
|
|
5; Red, green, blue, yellow, white
|
5; Red, green, blue, yellow, white
|
5; Red, green, blue, yellow, white
|
|
8
|
8
|
32
|
Installation type/mounting
|
|
|
|
Mounting position
|
vertical
|
vertical
|
vertical
|
Rack mounting possible
|
No
|
No
|
No
|
Front installation possible
|
Yes; Compatible with extension unit dimensions
|
Yes; Compatible with extension unit dimensions
|
Yes
|
Rail mounting possible
|
No
|
No
|
No
|
Wall mounting/direct mounting possible
|
No
|
No
|
No
|
Mounting in portrait format possible
|
Yes
|
Yes
|
Yes
|
Mounting in landscape format possible
|
Yes
|
Yes
|
Yes
|
maximum permissible angle of inclination without external ventilation
|
30°; To the front/rear
|
30°; To the front/rear
|
30°; To the front/rear
|
Mounting technology
|
Mounting clip
|
Mounting clip
|
Mounting clip
|
Number of slots for command devices and signaling units
|
0
|
0
|
0
|
Supply voltage
|
|
|
|
Type of supply voltage
|
DC
|
DC
|
DC
|
Rated value (DC)
|
24 V; 24 V can be looped through connector, interrupted when pulled
|
24 V; 24 V can be looped through connector, interrupted when pulled
|
24 V; 24 V looped through at connector, no interruption on pulling
|
permissible range, lower limit (DC)
|
20.4 V
|
20.4 V
|
20.4 V
|
permissible range, upper limit (DC)
|
28.8 V
|
28.8 V
|
28.8 V
|
Type of output
|
|
|
|
LED colors
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
Yes
|
Yes
|
Yes
|
|
Yes
|
Yes
|
Yes
|
|
Yes
|
Yes
|
Yes
|
|
Yes
|
Yes
|
Yes
|
Digital inputs
|
|
|
|
Number of digital inputs
|
8; Total inputs and outputs max. 8 and 1x SIL 2 or 2x SIL 3
|
8; Total inputs and outputs max. 8 and 1x SIL 2 or 2x SIL 3
|
32; Total inputs and outputs max. 32 and 2x SIL 2 or 4x SIL 3
|
Input voltage
|
|
|
|
|
24 V
|
24 V
|
24 V
|
Digital outputs
|
|
|
|
Number of digital outputs
|
8; Max. 8 inputs and outputs (total)
|
8; Max. 8 inputs and outputs (total)
|
16; Max. 32 inputs and outputs (total)
|
Short-circuit protection
|
Yes
|
Yes
|
Yes
|
Switching capacity of the outputs
|
|
|
|
|
100 mA
|
100 mA
|
100 mA
|
Output voltage
|
|
|
|
|
24 V; Non-isolated
|
24 V; Non-isolated
|
24 V; Non-isolated
|
Total current of the outputs
|
|
|
|
|
100 mA
|
100 mA
|
100 mA
|
|
800 mA
|
800 mA
|
800 mA
|
Interfaces
|
|
|
|
Number of industrial Ethernet interfaces
|
2; For the construction of lines and rings without external switch
|
2; For the construction of lines and rings without external switch
|
2; For the construction of lines and rings without external switch
|
Number of PROFINET interfaces
|
2; Incl. switch
|
2; Incl. switch
|
2; Incl. switch
|
Industrial Ethernet
|
|
|
|
|
2; Per port
|
2; Per port
|
2; Per port
|
|
2; Per port
|
2; Per port
|
2; Per port
|
Protocols
|
|
|
|
PROFINET
|
Yes; also 3rd party PLC
|
Yes; also 3rd party PLC
|
Yes; incl. shared device, 3rd party PLC
|
PROFINET CBA
|
No
|
No
|
No
|
IRT
|
Yes
|
Yes
|
Yes
|
MRP
|
Yes
|
Yes
|
Yes
|
PROFIsafe
|
No
|
Yes; 1x SIL 2 (two-channel) or 2x SIL 3 (single-channel) emergency stop sensor
|
Yes; 2x SIL 2 (two-channel) or 4x SIL 3 (single channel) emergency stop sensor
|
PROFIBUS
|
No
|
No
|
No
|
Test commissioning functions
|
|
|
|
Illuminant test
|
Yes; During switch on
|
Yes; During switch on
|
Yes; During switch on
|
Key and signal lamp test
|
Yes; Automatically when switching on
|
Yes; Automatically when switching on
|
Yes; Automatically when switching on
|
EMC
|
|
|
|
Emission of radio interference acc. to EN 55 011
|
|
|
|
|
Yes; Group 1, measured at a distance of 10 m
|
Yes; Group 1, measured at a distance of 10 m
|
Yes; Group 1, measured at a distance of 10 m
|
|
No
|
No
|
No
|
Degree and class of protection
|
|
|
|
IP (at the front)
|
IP65
|
IP65
|
IP65
|
Enclosure Type 4 at the front
|
No
|
No
|
No
|
Enclosure Type 4x at the front
|
Yes; Incl. NEMA12
|
Yes; Incl. NEMA12
|
Yes; Incl. NEMA12
|
IP (rear)
|
IP20
|
IP20
|
IP20
|
Standards, approvals, certificates
|
|
|
|
CE mark
|
Yes
|
Yes
|
Yes
|
cULus
|
Yes
|
Yes
|
Yes
|
RCM (formerly C-TICK)
|
Yes
|
Yes
|
Yes
|
KC approval
|
Yes
|
Yes
|
Yes
|
Suitable for safety functions
|
Yes
|
Yes
|
Yes
|
Marine approval
|
|
|
|
|
No
|
No
|
No
|
|
No
|
No
|
No
|
|
No
|
No
|
No
|
|
No
|
No
|
No
|
|
No
|
No
|
No
|
|
No
|
No
|
No
|
|
No
|
No
|
No
|
Use in hazardous areas
|
|
|
|
|
Yes
|
Yes
|
No; On request
|
|
Yes
|
Yes
|
No; On request
|
|
No
|
No
|
No
|
|
Yes
|
Yes
|
No; On request
|
|
Yes
|
Yes
|
No; On request
|
Ambient conditions
|
|
|
|
Ambient temperature during operation
|
|
|
|
|
0 °C
|
0 °C
|
0 °C
|
|
55 °C
|
55 °C
|
55 °C
|
|
|
|
|
|
0 °C
|
0 °C
|
0 °C
|
|
55 °C
|
55 °C
|
55 °C
|
|
|
|
|
|
0 °C
|
0 °C
|
0 °C
|
|
45 °C
|
45 °C
|
45 °C
|
|
|
|
|
|
0 °C
|
0 °C
|
0 °C
|
|
45 °C
|
45 °C
|
45 °C
|
|
|
|
|
|
0 °C
|
0 °C
|
0 °C
|
|
45 °C
|
45 °C
|
45 °C
|
Ambient temperature during storage/transportation
|
|
|
|
|
-20 °C
|
-20 °C
|
-20 °C
|
|
60 °C
|
60 °C
|
60 °C
|
Relative humidity
|
|
|
|
|
95 %; no condensation
|
95 %; no condensation
|
95 %; no condensation
|
Configuration
|
|
|
|
Configuration software
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
Yes
|
Yes
|
Yes
|
Functionality under WinCC (TIA Portal)
|
|
|
|
Process coupling
|
|
|
|
|
Yes; with ET 200pro CPU and ET 200S CPU
|
Yes; with ET 200pro CPU and ET 200S CPU
|
Yes; with ET 200pro CPU and ET 200S CPU
|
|
Yes
|
Yes
|
Yes
|
|
No
|
No
|
No
|
|
Yes; with F-CPU: STEP 7 V11 SP1 (or higher) and Safety V11 (or higher) or SIMATIC STEP 7 Basic V11 (or higher)
|
Yes; with F-CPU: STEP 7 V11 SP1 (or higher) and Safety V11 (or higher) or SIMATIC STEP 7 Basic V11 (or higher)
|
Yes; with F-CPU: STEP 7 V11 SP1 or higher and Safety V11 (or higher), without F-CPU STEP 7 or SIMATIC STEP 7 Basic V11 (or higher)
|
|
No
|
No
|
No
|
|
Yes
|
Yes
|
Yes
|
|
No
|
No
|
No
|
|
No
|
No
|
No
|
|
No
|
No
|
No
|
|
No
|
No
|
No
|
|
No
|
No
|
No
|
|
No
|
No
|
No
|
|
No
|
No
|
No
|
|
No
|
No
|
No
|
|
No
|
No
|
No
|
Mechanics/material
|
|
|
|
Enclosure material (front)
|
|
|
|
|
Yes
|
Yes
|
No
|
|
No
|
No
|
Yes
|
Service life
|
|
|
|
|
1 500 000
|
1 500 000
|
1 500 000
|
|
100 %
|
100 %
|
100 %
|
Dimensions
|
|
|
|
Width of the housing front
|
98 mm
|
98 mm
|
295 mm
|
Height of housing front
|
155 mm
|
155 mm
|
155 mm
|
Mounting cutout, width
|
68 mm; Max. thickness of mounting plate 2 - 6 mm
|
68 mm; Max. thickness of mounting plate 2 - 6 mm
|
277 mm; Max. thickness of mounting plate 2 - 6 mm
|
Mounting cutout, height
|
129 mm
|
129 mm
|
137 mm
|
Overall depth
|
49 mm; Incl. angled SIMATIC Ethernet connector
|
49 mm; Incl. angled SIMATIC Ethernet connector
|
69 mm; Incl. angled SIMATIC Ethernet connector
|
Weights
|
|
|
|
Weight without packaging
|
280 g
|
280 g
|
1 220 g
|