产品简介
WIKA 712.15.100 低温行业用铜差压压力表
WIKA 712.15.100 低温行业用铜差压压力表
产品价格:¥1000
上架日期:2013-10-11 15:29:02
产地:德国
发货地:北京
供应数量:不限
最少起订:1件
浏览量:165
资料下载:暂无资料下载
其他下载:暂无相关下载
详细说明

    WIKA 712.15.100 732.15.160

    低温行业用铜差压压力表 无粘稠液体

    Differential pressure gauge
    Model 712.15.100, Cu-alloy
    Model 732.15.100, stainless steel version







        Fig. top: Differential pressure gauge model 712.15.100
        Fig. centre: Option valve manifold with working pressure indication
        Fig. bottom: Option adapter for flange mounting

     

       Applications
        ■ Level measurements in closed tanks, particularly in cryotechnology
        ■ Filter monitoring
        ■ Monitoring and control of pumps
        ■ For gaseous and liquid media that are not highly viscous or crystallising and have no suspended solids

     

        Special features
        ■ Differential pressure measuring ranges from 0 … 80 mbar to 0 ... 1725 mbar
        ■ High working pressure (static pressure) of 50 bar
        ■ Overpressure safety either side up to 50 bar
        ■ Very compact design
        ■ Optionally compact valve manifold with working pressure indication

     

        Debion

     

        These high-quality gauges are characterised by their compact and robust design and are primarily used for level measurement on liquid gas tanks.


        An optional valve manifold for flange mounting with working pressure indication makes the central measurement of both level and working pressure possible in the one instrument.

     

        The level display can be supplied with an optional, integrated 4 … 20 mA, 2-wire transmitter. Switch contacts for level and working pressure, as well as a transmitter for the working pressure can be retrofitted on site.

        The standard centre distance of 37 mm between the process connections can be adapted to a custom centre distance of 31 mm or 54 mm using adapters for flange mounting.

     

     

        Design and operating principle
        Pressures p1 and p2 act on the media chambers ⊕ and ?, which are separated by an elastic diaphragm (1).
        The differential pressure (Δp = p1 - p2) leads to an axial deflection of the diaphragm against the measuring range spring (2).
        The deflection, which is proportional to the differential pressure, is transmitted to the movement (5) in the indicating case (4) via a pressure-tight and low friction lever mechanism (3).
        Overpressure safety is provided by bl bolsters (6) resting against the elastic diaphragm.

     

       Illustration of the principle



                    Mounting according to affixed symbols,
                     ⊕ high pressure and ? low pressure

     

       Standard version

       Differential pressure gauge
        Model 712.15.100
        Model 732.15.100



     

        Specifications
        Nominal size NS 100 (level indication)
        Accuracy class 2.5 (option: Class 1.6 or class 1.0)
        Scale ranges 0 ... 80 mbar to 0 ... 1725 mbar
        Max. working pressure (static pressure) 50 bar
        Overpressure safety either side up to 50 bar
        Permissible ambient temperatures -40 °C … +80 °C, -40 °C … +60 °C with oxygen
        Permissible medium temperatures -40 °C … +80 °C, -40 °C … +60 °C with oxygen
        Ingress protection IP 65 per EN 60529 / IEC 529
        Process connections (wetted)
        Standard 2 x G 1/4, female, lower mount (LM), centre distance 37 mm
        Option with adapter see page 5
        Measuring cell flanges (wetted) Model 712.15: Cu-alloy CW614N (CuZn39Pb3)
        Model 732.15: Stainless steel 316L
        Pressure elements (wetted) Compression spring, stainless steel 1.4310
        Separating diaphragm, NBR
        Transmission parts, stainless steel 1.4301 and 1.4305
        Movement Wear parts stainless steel
        Dial White aluminium (see section 'Scale designs')
        Pointer Adjustable pointer, black aluminium
        Zero adjustment By means of adjustable pointer
        Case / slip-on bezel Stainless steel, with clip fasteners
        Window Polycarbonate (PC)

     

        Scale designs
        The dials can be made to customer‘s requirements and also with multiple scales.
        These can be printed with all usual units on them, e.g. kg, litre, m3, mmH2O, inchH2O, % etc.. Red marks for maximum fill level, customer logos and other custom printing are likewise possible. If desired, we can carry out the calculation
    for the tank fuel level from drawings of the tank geometry, and then make the appropriate scales.

     

        Dimensions in mm


        Option
        Valve manifold (wetted) with mounted working pressure gauge



       Specifications
        Valves 2 x shut-off valve, 1 x pressure equalising valve
        Test connection M20 x 1.5 with sealing cap (DIN 16287-A)
        Valve body Model 712.15: Cu-alloy CW614N (CuZn39Pb3); model 732.15: Stainless steel 316L
        Spindle with conical nipple Model 712.15: Cu-alloy; model 732.15: Stainless steel 316L
        Packing/sealing NBR/PTFE
             With the valve fully-opened, the spindle area is isolated from the process by a bllic seal, the packing is not loaded and the spindle thread is not in contact with the measured media.
        Working pressure gauge
           Standard Model 232.50.63, wetted parts stainless steel
              (for specifications and design details see data sheet PM 02.02)
           Option Model 212.20.100, wetted parts Cu-alloy
              (for specifications and design details see data sheet PM 02.01)


        With a single order, all parts necessary for the fitting to the differential pressure gauge are included in the delivery: 4 x hexagon screws M8 x 16 , 2 x O-ring seal



     

        Option
       Adapter for process connection
        The adapters can be flange mounted either directly to the differential pressure gauge or to the valve manifold.

     

       Specifications
        Material Model 712.15: Cu-alloy CW614N (CuZn39Pb3); model 732.15: Stainless steel 316L
        Process connections (wetted) 2 x G 1/4, female, lower mount (LM), centre distance 31 mm or 54 mm or 2 x 1/4 NPT, female, centre distance 31 mm, 37 mm or 54 mm

     

       Option
        Transmitter for level indication

        Standard version model 891.44
        Ex version model 892.44   

     

        WIKA differential pressure gauges with an integrated model 89x.44 transmitter combine all the advantages of an on-site mechanical display with the demands modern industry makes for electrical signal transmission for the acquisition of
    measured values.
        The transmitter is integrated into the case of the level display. With multiple scales (option) the output signal of 4 ... 20 mA corresponding to each, can be stored in a microprocessor.
        The output signal can be changed over to the desired fluid type by rotating the optional BCD switch (accessible through a cover cap on the left side of the case) using a screwdriver.
        Transmitter for level display
        With a single order, all parts necessary for the fitting to the differential pressure gauge or to the valve manifold are included in the delivery: 2 x hexagon screws M8 x 16, 2 x hexagon screws M8 x 28, 2 x nut M8 and 2 x O-ring seal

       Specifications

        Models 891.44 and 892.44 (Ex version)
        Supply voltage UB DC V 12 < UB ≤ 30 (min. 14 with Ex version)
        Influence of supply voltage % Full scale/10 V ≤ 0.1
        Permissible residual ripple % ss ≤ 10
        Output signal 4 … 20 mA, 2-wire
        Permissible max. load RA for non-Ex versions, model 891.44:
          RA ≤ (UB - 12 V) / 0.02 A with RA in Ohm and UB in Volt for Ex versions, model 892.44:
          RA ≤ (UB - 14 V) / 0.02 A with RA in Ohm and UB in Volt
        Effect of load % Full scale ≤ 0.1

       Adjustment
        Zero point, electrical Adjustment of the zero point through brief bridging of terminals 5 and 6 or using the 'scale selection switch' option, selectable via button 1)
        Scale selection 4 scales selectable via BCD switch
        Linearity % of span ≤ 1.0 % (terminal b)

        Permissible
        ambient temperatures °C -40 … +80, -40 … +60 with oxygen
        Compensated temp. range °C -40 … +80
        Temperature coefficients in the compensated temp. range
        Mean TK of zero % of span / 10 K ≤ 0.3
        Mean TC span % of span / 10 K ≤ 0.3
          1) Only possible within 30 seconds of connecting the supply voltage

     

        ?CE conbity   
        EMC directive  ATEX directive  
        2004/108/EC, EN 61326 emission (group 1, class B) and interference immunity (industrial application)  94/9/EC, II 2 G Ex ia IIC  

        Further specifications Models 891.44 and 892.44 (Ex version)
        Conbity specifications Ex version
        ■ Supply voltage Ui DC V 14 ... max. 30
        ■ Short circuit current Ii mA max. 100
        ■ Power Pi W max. 1
        ■ Internal capacitance Ci nF 12
        ■ Internal inductance Li mH negligible
        Medium temperature °C -40 … +80, -40 … +60 with oxygen
        Ambient temperature °C -40 … +60 (T6)
        Electrical connection Angular connector, 180° rotatable, wire protection, cable gland M20 x 1.5, incl.strain relief, connection cable: Outer diameter 7 ... 13 mm, conductor cross-section 0.14 ... 1.5 mm2, temperature resistance up to 60 °C
        Wiring protection Protection against reverse polarity and overvoltage
        Ingress protection IP 65 per EN 60529 / IEC 529
        Wiring details, 2-wire
        Earth, connected to case 1)
         UB+/Sig
         +0 V/Sig-
        Terminals 3, 4, 5 and 6: only for internal use 1) This connection must not be used for equipotential bonding. The instrument must be incorporated in the equipotential bonding via the process connection.

     

       ?Option 
        Transmitter for working pressure indication  
        Standard version model A-10  
        or Ex version model IS-20  

        The transmitters for the working pressure are screwed in sideways on the left side of the minus media chamber and can, if necessary, be retrofitted on site.
        Pressure connection of the transmitter:
        G 1/4 (male)

     

        Option
        Switch contacts for level and/or working pressure indicators A modular system of electromechanical and electronic switch contacts with plug connection, also suitable for retrofitting on site, can be fitted both to the level display and to the working
    pressure indication. They consist of self-contained units, which can be fitted to any pointer pressure gauge within a few minutes. The connection to the instrument pointer is made by means of a special yoke so that a carrier pin at the pointer itself is not needed. The set value pointer of the installed switch contacts are adjusted, from the outside, to the value at which the switching operation is to take place, using the adjustment lock with a separate or integral key. A coupler connector, an M3 x 20 centring screw and a seal are included in the delivery.
        Selectable are the following single and double contact models built into a self-contained unit
        ■ Model 828 1) , magnetic snap-b contact
        ■ Model 838 1) , inductive contact gauge

       Switching functions
        The following applies, as a general rule, to the contact functions of the model 828 1) in connection with our standard settings:
        Index 1 according to the contact type no. means:
            Contact closes the circuit when the set point is exceeded
        Index 2 according to the contact type no. means:
            Contact opens the circuit when the set point is exceeded
        Index 3 according to the contact type no. means:
            When the set value is exceeded, one circuit is opened and one circuit is closed simultaneously (change-over contact)

        The following applies, as a general rule, to the contact  functions of the model 838 1) inductive contacts in connection with our standard settings:
        Index 1 according to the contact type no. means:
              Contact closes the control circuit when the set point is exceeded (flag disengages from control head)
        Index 2 according to the contact type no. means:
              Contact opens the control circuit when the set point is exceeded (flag engages with control head)
        The switching functions are based on a clockwise rotational
    motion of the instrument pointer.

     

    欢迎致电咨询订购WIKA 712.15.100 732.15.160 低温行业用铜差压压力表 无粘稠液体

    电话:010-51669912 56291930 15910733293

    传真:010-51669912

    QQ:823377546 1491421115 2636968574

    邮箱:sales@zoriver.cn

    公司官网:http://www.zoriver.cn          http://www.zoriver.com.cn

在线询盘/留言
  • 免责声明:以上所展示的信息由企业自行提供,内容的真实性、准确性和合法性由发布企业负责,本网对此不承担任何保证责任。我们原则 上建议您选择本网高级会员或VIP会员。
    0571-87774297