6ES7532-5HD00-0AB0。西门子SM532模拟量输出模块,可以将16位数字值转换为电流或电压并输出到过程。例如,它们适合控制比例阀或小型伺服驱动器。提供有2、4和8通道模拟量输出模块。模拟量模块只需要极短的转换时间,用于连接模拟执行器,无需附加放大器,可应对更为复杂的自动化任务。
西门子工业自动化控制器、可编程控制器,西门子S7-1500PLC,产品选型、报价、销售,敬请致电上海启水自动化科技有限公司:
联系人 :颜克成( 销售经理 )24小时服务热线 :17621653310
电话( bbb ):021-33550656 传真(Fax): 021-33556143
工作QQ: 1013283296
地址( Add ):上海市松江区广富林路4855弄52号3楼
6ES7532-5HD00-0AB0
西门子SM532模拟量输出模块 销售订货号:
|
6ES7532-5HD00-0AB0
SIMATIC S7-1500,AQ 4:模拟输出模块,4AQ,U/I
|
|
6ES7532-5HF00-0AB0
SIMATIC S7-1500,AQ 8:模拟输出模块,8AQ,U/I ,高速
|
|
6ES7532-5NB00-0AB0
SIMATIC S7-1500, ANALOG OUTPUT MODULE AQ 2 X U/I ST, 16 BITS OF RESOLUTION, ACCURACY 0.3 %. 2 CHANNELS IN GROUPS OF 2, DIAGNOSIS, SUBSTITUTE VALUE INCL. FRONT CONNECTOR PUSH-IN, FEEDING ELEM., SHIELDING ELEM., SHIELDING CLAMP
|
|
6ES7532-5ND00-0AB0
SIMATIC S7-1500, ANALOG OUTPUT MODULE AQ 4 X U/I HF, 16 BITS OF RESOLUTION, ACCURACY 0.1%, 4 CHANNELS IN GROUPS OF 1; COMMON MODE VOLTAGE: 30V AC/60V DC, DIAGNOSIS, SUBSTITUTE VALUE INCL. INFEED ELEMENT, SHIELD CLAMP AND SHIELD TERMINAL
|
更多西门子S7-1500销售订货型号:
SM521数字量输入模块
6ES7521-1BH00-0AB0
6ES7521-1BH50-0AA0
6ES7521-1BL00-0AB0
6ES7521-1FH00-0AA0
SM522数字量输出模块
6ES7522-1BF00-0AB0
6ES7522-1BH00-0AB0
6ES7522-1BL00-0AB0
6ES7522-5FF00-0AB0
6ES7522-5HF00-0AB0
SM531模拟量输入模块
6ES7531-7KF00-0AB0
6ES7531-7NF10-0AB0
S7-1500安装导轨
6ES7590-1AB60-0AA0
6ES7590-1AE80-0AA0
6ES7590-1AF30-0AA0
6ES7590-1AJ30-0AA0
6ES7590-1BC00-0AA0
S7-1500PLC电源模块
6EP1332-4BA00
6EP1333-4BA00
6ES7505-0KA00-0AB0
6ES7505-0RA00-0AB0
6ES7507-0RA00-0AB0
西门子S7-1500PLC CPU主机模块
6ES7 516-3AN00-0AB0 西门子PLC S7-1500 CPU 1516-3 PN/DP:1 MB 程序,5 MB 数据;10 ns ;集成 2PN 接口,1 以太网接口,1DP 接口
6ES7 513-1AL00-0AB0 西门子PLC S7-1500 CPU 1513-1 PN:300 KB 程序,1.5 MB 数据;40 ns;集成 2PN 接口,
6ES7 511-1AK00-0AB0 西门子PLC S7-1500 CPU 1511-1 PN:150 KB 程序,1 MB 数据;60 ns;集成 2PN 接口,
西门子PLC S7-1500通讯模块
6ES7 540-1AB00-0AA0 西门子PLC S7-1500 PtP RS422/485 通讯模块
6ES7 541-1AD00-0AB0 西门子PLC S7-1500 PtP RS232 ,高性能通讯模块
6ES7 541-1AB00-0AB0 西门子PLC S7-1500 PtP RS422/485 ,高性能通讯模块
6ES7 540-1AD00-0AA0 西门子PLC S7-1500 PtP RS232通讯模块
西门子PLC S7-1500接口模块
6ES7 155-5BA00-0AB0 西门子PLC S7-1500 ET 200MP Profibus接口模块
6ES7 155-5AA00-0AB0 西门子PLC S7-1500 IM 155-5 2PN 接口,Pro?net 接口模块
6ES7532-5HD00-0AB0
西门子SM532模拟量输出模块 产品简介:
提供有以下模拟量输出模块:AQ 8xU/I HS:8通道模拟量输出模块;16 位分辨率;准确度 +/-0.3%;一个电压组;可设置诊断参数;可设置输出的替代值;高速 8 通道,125 μs;等时同步模式;在执行时间中进行校准,模块宽度 35 mm。
有关安装导轨上模块的尺寸图以及带开放式前面板模块的尺寸图,请参见附录。请务必遵循在控制柜、控制室等地方安装时的具体尺寸要求。
图片: AQ 4xU/I ST 模块的尺寸图
图片: AQ 4xU/I ST 模块的尺寸图,带开放式前面板的侧视图
模块数据记录的结构相同,而与是否通过 PROFIBUS DP 或 PROFINET IO 组态模块无关。在使用 GSD 文件组态模块时,请注意某些参数的设置之间都相互关联。在传送到模块后,模块仅对参数进行真实性检查。
下表列出了相互依赖的参数。
列表: 使用 GSD 文件进行组态时参数的相关性
设备特定参数(GSD 文件) |
相关参数 |
---|---|
对 M 短路 |
仅针对输出类型电压 |
断路 |
仅针对输出类型电流 |
替换值 |
仅当组态对 CPU STOP 的响应 -> 输出替换值时 |
可以在 RUN 模式下对模块进行参数分配(例如,在 RUN 模式下编辑所选通道的电压或电流值,而不影响其它通道)。
使用 WRREC 指令可通过数据记录 64 到 67 将参数传送到模块。在 CPU 中不会更改 STEP 7 中设置的参数。即,STEP 7 中设置的参数在重新启动后仍然有效。
在传送到模块后,模块仅对参数进行真实性检查。
模块将忽略在 WRREC 指令传输参数期间发生的错误,并继续使用之前的参数分配进行操作。 但会将相应的错误代码写入 STATUS 输出参数中。
有关 WRREC 指令的说明和错误代码,请参见 STEP 7 在线帮助。
如果在 PROFIBUS DP 接口模块后面操作模块,将不回读参数数据记录 0 和 1。对于回读参数数据记录 0 和 1,可以获取诊断数据记录 0 和 1。有关详细信息,请参见 Internet 上 PROFIBUS DP 接口模块设备手册的“中断”部分。
数据记录 64 到 67 中的通道参数可用于对 1x 4 通道进行组态,具体分配如下所示:
对于 4 x 1 通道组态,该模块有 4 个子模块(每个子模块有一个通道)。 通道参数将位于数据记录 64 中,具体分配如下所示:
进行数据记录传输时,将寻址相应的子模块。
下图举例说明了数据记录 64 对应通道 0 的结构。通道 1 到 3 的结构相同。 字节 0 和字节 1 中的值为固定值,不可更改。
通过将相应位设置为“1”,启用参数。
下表列出了模拟量输出模块的所有输出类型及其代码。 在相应通道数据记录的字节 2 中输入这些代码(参见上图)。
列表: 输出类型代码
输出类型 |
代码 |
---|---|
禁用 |
0000 0000 |
电压 |
0000 0001 |
电流 |
0000 0010 |
下表列出了模拟量输出模块的所有电压和电流输出范围及其代码。 在任何情况下,都将在相应数据记录的字节 3 中输入这些代码(请参见上图)。
列表: 输出范围代码
电压输出范围 |
代码 |
1 V 到 5 V 0 V 到 10 V ±10 V |
0000 0011 0000 0010 0000 0000 |
电流输出范围 |
代码 |
0 mA 到 20 mA 4 mA 到 20 mA ±20 mA |
0000 0001 0000 0010 0000 0000 |
下表列出了有效替换值的所有输出范围。 在相应通道数据记录的字节 6 和 7 中输入这些替换值(参见上图)。 有关输出范围的二进制表示,请访问 Internet 上的功能手册 SIMATIC 的模拟值处理。
列表: 输出范围的有效替换值
输出范围 |
有效替换值 |
±10 V 1 V 到 5 V 0 V 到 10 V |
-32512 ... +32511 -6912 ... +32511 0 ... +32511 |
±20 mA 4 mA 到 20 mA 0 mA 到 20 mA |
-32512 ... +32511 -6912 ... +32511 0 ... +32511 |
模拟值表示:
各模拟值均以与变量左对齐的方式写入。 标记为“x”的位设置为“0”。
列表: 模拟值的精度
以位表示的精度( |
值 |
模拟值 |
||
---|---|---|---|---|
十进制 |
十六进制 |
高位字节 |
低位字节 |
|
16 |
1 |
1H |
符号 0 0 0 0 0 0 0 |
0 0 0 0 0 0 0 1 |
下表列出了按双极性和单极性进行数字化表示的输出范围。 精度为 16 位。
列表: 双极性输出范围
十进制值 |
输出值(百分比) |
数据字 |
范围 |
|||||||||||||||
215 |
214 |
213 |
212 |
211 |
210 |
29 |
28 |
27 |
26 |
25 |
24 |
23 |
22 |
21 |
20 |
|||
32511 |
117,589 |
0 |
1 |
1 |
1 |
1 |
1 |
1 |
0 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
最大输出值* |
32511 |
117,589 |
0 |
1 |
1 |
1 |
1 |
1 |
1 |
0 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
过冲范围 |
27649 |
100,004 |
0 |
1 |
1 |
0 |
1 |
1 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
1 |
|
27648 |
100,000 |
0 |
1 |
1 |
0 |
1 |
1 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
额定范围 |
1 |
0,003617 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
1 |
|
0 |
0,000 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
|
-1 |
-0,003617 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|
-27648 |
-100,000 |
1 |
0 |
0 |
1 |
0 |
1 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
|
-27649 |
-100,004 |
1 |
0 |
0 |
1 |
0 |
0 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
下冲范围 |
-32512 |
-117,593 |
1 |
0 |
0 |
0 |
0 |
0 |
0 |
1 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
|
-32512 |
-117,593 |
1 |
0 |
0 |
0 |
0 |
0 |
0 |
1 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
最小输出值** |
列表: 单极性输出范围
十进制值 |
输出值(百分比) |
数据字 |
范围 |
|||||||||||||||
215 |
214 |
213 |
212 |
211 |
210 |
29 |
28 |
27 |
26 |
25 |
24 |
23 |
22 |
21 |
20 |
|||
32511 |
117,589 |
0 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
x |
x |
x |
x |
x |
x |
x |
x |
最大输出值* |
32511 |
117,589 |
0 |
1 |
1 |
1 |
1 |
1 |
1 |
0 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
过冲范围 |
27649 |
100,004 |
0 |
1 |
1 |
0 |
1 |
1 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
1 |
|
27648 |
100,000 |
0 |
1 |
1 |
0 |
1 |
1 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
额定范围 |
1 |
0,003617 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
1 |
|
0 |
0,000 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
|
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
最小输出值** |
6ES7532-5HD00-0AB0 技术参数:
SIMATIC S7-1500, 模拟量输出模块 AQ 4xU/I ST, 16 位 分辨率, 准确度 0,3%. 4 通道 8 个一组, 诊断;替换值 inkl. Einspeiseelement, 屏蔽支架 和 屏蔽端子 | ||
一般信息 | ||
产品类型标志 | AQ 4xU/I ST | |
硬件功能状态 | FS01 | |
固件版本 | V2.0.0 | |
● 可更新固件 | 是 | |
产品功能 | ||
● I&M 数据 | 是; I&M0 至 I&M3 | |
● 可变输出范围 | 否 | |
附带程序包的 | ||
● STEP 7 TIA 端口,可组态 / 已集成,自版本 | V12 / V12 | |
● STEP 7 可组态/ 已集成,自版本 | V5.5 SP3 / - | |
● PROFIBUS 版本 GSD 版 / GSD 修订版以上 | V1.0 / V5.1 | |
● PROFINET 版本 GSD 版 / GSD 修订版以上 | v2.3 / - | |
运行模式 | ||
● 过采样 | 否 | |
● MSO | 是 | |
运行中的 CiR 配置 | ||
可在 RUN 模式下更改参数分配 | 是 | |
可在 RUN 模式下校准 | 是 | |
电源电压 | ||
额定值 (DC) | 24 V | |
允许范围,下限 (DC) | 20.4 V | |
允许范围,上限 (DC) | 28.8 V | |
反极性保护 | 是 | |
输入电流 | ||
耗用电流,最大值 | 190 mA; 24 V DC 供电时 | |
功率 | ||
来自背板总线的功率输出 | 0.6 W | |
功率损失 | ||
功率损失,典型值 | 4 W | |
模拟输出 | ||
模拟输出端数量 | 4 | |
电压输出,短路保护 | 是 | |
电压输出,短路电流,最大值 | 24 mA | |
电流输出,空载电压,最大值 | 22 V | |
循环时间(所有通道) 最小值 | 3.2 ms; 与激活的通道数量无关 | |
输出范围,电压 | ||
● 0 至 10 V | 是 | |
● 1 V 至 5 V | 是 | |
● -5 V 至 +5 V | 否 | |
● -10 V 至 +10 V | 是 | |
输出范围,电流 | ||
● 0 至 20 mA | 是 | |
● -20 mA 至 +20 mA | 是 | |
● 4 mA 至 20 mA | 是 | |
执行器连接 | ||
● 对于两线制接口电压输出 | 是 | |
● 对于四线制接口电压输出 | 是 | |
● 对于两线制接口电流输出 | 是 | |
负载电阻(在额定输出范围内) | ||
● 电压输出端的最小值 | 1 kΩ; 1 ... 5 V 时 0.5 kOhm | |
● 电压输出端的电容负载,最大值 | 1 μF | |
● 电流输出端的最大值 | 750 Ω | |
● 电流输出端的电感负载,最大值 | 10 mH | |
导线长度 | ||
● 屏蔽,最大值 | 800 m; 电流中,电压时 200 m | |
输出端的模拟值构成 | ||
集成和转换时间/每通道分辨率 | ||
● 带有过调制的分辨率(包括符号在内的位数),最大值 | 16 bit | |
● 转换时间(每个通道) | 0.5 ms | |
起振时间 | ||
● 对于电阻负载 | 1.5 ms | |
● 对于电容负载 | 2.5 ms | |
● 对于电感负载 | 2.5 ms | |
误差/精度 | ||
输出波纹(与输出范围有关,带宽 0 至 50 kHz),(+/-) | 0.02 % | |
线性错误(与输出范围有关),(+/-) | 0.15 % | |
温度错误(与输出范围有关),(+/-) | 0.002 %/K | |
输出端之间的串扰,最大值 | -100 dB | |
25 °C 时起振状态下的重复精度(与输出范围有关),(+/-) | 0.05 % | |
整个温度范围内的操作错误限制 | ||
● 电压,与输出范围有关,(+/-) | 0.3 % | |
● 电流,与输出范围有关,(+/-) | 0.3 % | |
基本错误限制(25 °C 时的操作错误限制) | ||
● 电压,与输出范围有关,(+/-) | 0.2 % | |
● 电流,与输出范围有关,(+/-) | 0.2 % | |
等时模式 | ||
节拍同步运行(应用程序至端口同步) | 否 | |
报警/诊断/状态信息 | ||
诊断功能 | 是 | |
可接入替代值 | 是 | |
报警 | ||
● 诊断报警 | 是 | |
诊断信息 | ||
● 电源电压监控 | 是 | |
● 断线 | 是; 仅限电流输出类型 | |
● 短路 | 是; 仅限电压输出类型 | |
● 溢出/下溢 | 是 | |
诊断显示 LED | ||
● RUN LED | 是; 绿色 LED | |
● ERROR LED | 是; 红色 LED | |
● 电源电压监控 (PWR-LED) | 是; 绿色 LED | |
● 通道状态显示 | 是; 绿色 LED | |
● 用于通道诊断 | 是; 红色 LED | |
● 用于模块诊断 | 是; 红色 LED | |
电位隔离 | ||
通道的电势分离 | ||
● 在通道之间 | 否 | |
● 在通道之间,分组点数 | 4 | |
● 在通道和背板总线之间 | 是 | |
● 在通道和负载电压 L+ 之间 | 是 | |
允许的电位差 | ||
S 和 MANA (UCM) 之间 | DC 8 V | |
绝缘 | ||
绝缘测试,使用 | 707 V DC(测试类型) | |
分布式运行 | ||
按优先级启动 | 否 | |
尺寸 | ||
宽度 | 35 mm | |
高度 | 147 mm | |
深度 | 129 mm | |
重量 | ||
重量,约 | 310 g |