Single Motor Module in booksize bat C/D types, 3 A to 30 A
The Single Motor Modules in booksize bat feature the following connections and interfaces as standard:
-
2 DC b connections via integrated DC b busbars
-
1 electronics power supply connection via integrated 24 V DC bars
-
3 DRIVE‑CLiQ sockets
-
1 motor connection (connector X1 for C/D type is not included in the scope of delivery)
-
1 Safe Stop b
-
1 safe motor brake control
-
1 temperature sensor b for KTY84‑130, Pt1000 or PTC (Pt1000 can be used from firmware V4.7 HF17)
-
2 PE (protective earth) connections – a PE connection is integrated in the connector for C/D types
The status of the Motor Modules is indicated via two multi-color LEDs.
The shield is integrated in the housing of 50 mm and 100 mm (1.97 in and 3.94 in) wide Motor Modules, which results in an improved shield connection. A shield connection plate can be supplied for 150 mm, 200 mm and 300 mm (5.91 in, 7.87 in and 11.81 in) wide modules. On these modules, the motor cable shield can be connected using a hose clip.
Motor Modules in booksize bat C/D types, 3 A to 30 A
Overview of available Single Motor Modules in booksize bat C/D types
-
C type: Optimized for continuous load with up to 200 % overload (continuous motion)
-
D type: Optimized for highly dynamic, intermittent duty cycles with up to 300 % overload (discontinuous motion)
Devices in booksize bat C/D types are optimized for multi-axis applications and are mounted next to one another. The connection for the common DC b is an integral feature. The device is internally air cooled.
The new Motor Modules in booksize bat C/D types have been developed to be fully compatible with the booksize series regarding spare parts. The advantages of this new product include:
-
The amount of space required beneath the Motor Modules has been reduced thanks to improvements in the design and a new motor plug connector
-
With the new motor plug connector design, the brake conductors and the PE connection are integrated directly in the plug connector
-
The motor connections on the Double Motor Module are located side by side, resulting in a significantly improved level of accessibility
-
The fan can be simply replaced without having to remove the Motor Module
The signal cable shield can be connected to the Motor Module by means of a shield connection terminal, e.g. Weidmüller type KLBü 3-8 SC.
The scope of supply of the Motor Modules includes:
-
DRIVE‑CLiQ cable appropriate to the b of the Motor Module for connection to the adjacent Motor Module, length = b of Motor Module + 0.06 m (0.20 ft)
-
Jumper for connecting the 24 V DC busbar to the adjacent Motor Module
-
Connector X21
-
Connector X11 for the motor brake connection
(for Motor Modules with a rated output current of 45 A to 200 A)
-
2 blanking plugs for sealing unused DRIVE-CLiQ sockets
-
Fan insert for the 132 A and 200 A Motor Modules
(the voltage for the fan insert is supplied by the Motor Module)
-
1 set of warning labels in 30 languages
-
1 shield connection clamp
(for booksize bat C/D types)