满足不同客户需求,诚信走天下,走遍天下有朋友西门子PLC代理商 西门子PLC模块代理商 西门子PLC通讯模块代理商 西门子PLC模拟量模块代理商 西门子PLC模块总代理商西门子变频器 触摸屏 代理商
The SINAMICS G120 frequency inverter is designed to provide precise and cost-effective speed/torque control of three-phase motors.
With different device versions (frame sizes FSA to FSGX) in a power range from 0.37 kW to 250 kW (0.5 hp to 400 hp), it is suitable for a wide variety of drive solutions.
Example: SINAMICS G120, frame sizes FSA, FSB and FSC; each with Power Module, CU240E‑2 F Control Unit and Basic Operator Panel BOP-2
Example: SINAMICS G120, frame sizes FSD, FSE and FSF; each with Power Module, CU240E‑2 F Control Unit and Inbligent Operator Panel IOP
Example: SINAMICS G120, frame size FSGX; with Power Module, CU240E‑2 F Control Unit and Basic Operator Panel BOP-2
Operator-friendly design
SINAMICS G120 is a modular inverter system that essentially comprises two function units:
-
Control Unit (CU)
-
Power Module (PM)
The Control Unit controls and monitors the Power Module and the connected motor using several different closed-loop control types that can be selected. It supports communication with a local or central controller and monitoring devices.
The Power Module supplies the motor in the power range 0.37 kW to 250 kW (0.5 hp to 400 hp). It features state-of-the-art IGBT technology with pulse-b-modulated motor voltage and selectable pulse frequency. Comprehensive protection functions provide a high degree of protection for the Power Module and the motor.
The Control Units can be combined with the following Power Modules:
Control Units
|
Power Modules degree of protection IP20
|
|
PM240‑2
|
PM240
|
PM250
|
CU230P‑2
|
✓
|
✓
|
✓
|
CU240E‑2
|
✓
|
✓
|
✓
|
CU250S‑2
|
✓
|
✓
|
✓
|
Safety Integrated
SINAMICS G120 standard inverters are available in different versions for safety-related applications. The PM240‑2 and PM250 Power Modules are already designed for Safety Integrated. PM240 Power Modules, frame size FSGX (i.e. 160 kW/250 hp and higher) are approved only for the Basic Safety functions (STO, SS1, and SBC). A drive can be combined with a Control Unit with safety functions (see overview) in order to create a Safety Integrated drive. The availability of Safety Integrated functions depends on the type of Control Unit.
Control Unit
|
Basic Safety functions
|
Extended Safety functions
|
|
STO
|
SS1
|
SBC 1)
|
SLS
|
SDI
|
SSM
|
CU230P‑2
|
–
|
–
|
–
|
–
|
–
|
–
|
CU240E‑2
|
✓
|
–
|
–
|
–
|
–
|
–
|
CU240E‑2 F
|
✓
|
✓
|
–
|
✓
|
✓
|
✓ 2)
|
CU250S‑2
|
✓
|
✓
|
✓
|
✓ 3)
|
✓ 3)
|
✓ 3)
|
1) The SBC function can be utilized only if a Safe Brake Relay is installed.
2) SSM possible only for CU240E‑2 DP‑F / CU240E‑2 PN‑F Control Units with PROFIsafe.
3) With license for Extended Safety functions.
Basic Safety functions (certified according to IEC 61508 SIL 2, and EN ISO 13849‑1 PL d and Category 3)
-
Safe Torque Off (STO)
to protect against active movement of the drive
-
The PM240‑2 Power Modules, frame sizes FSD to FSF additionally offer STO acc. to IEC 61508 SIL 3 and EN ISO 13489‑1 PL e and Category 3.
-
Safe Stop 1 (SS1)
for continuous monitoring of a safe braking ramp
-
Safe Brake Control (SBC) is used to safely control a holding
brake. When enabled, SBC is always activated at the same time as STO. The Safe Brake Relay is used for SBC.
Extended Safety functions (certified according to IEC 61508 SIL 2 and EN ISO 13849‑1 PL d and Category 3)
-
Safely Limited Speed (SLS)
for protection against dangerous movements on exceeding a speed limit
-
Safe Direction (SDI)
This function ensures that the drive can only rotate in the selected direction.
-
Safe Speed Monitoring (SSM)
This function signals if a drive operates below a specific speed/feed velocity.
Basic Safety and Extended Safety functions can be activated via PROFIsafe or by means of the safety bs.
None of the safety functions require a motor encoder and they are thus cheaper and easier to implement. Existing systems in particular can be simply updated with safety technology without the need to change the motor or mechanical system.
The Safe Torque Off (STO) function can be used without restriction for all applications. The SS1, SLS, SSM and SDI functions are only permissible for applications where the load can never accelerate when the inverter is switched off. They are therefore not permitted for applications involving pull-through loads such as hoisting gear and unwinders.
Additional inbation is provided in chapter Highlights, section Safety Integrated.
Efficient Infeed Technology
The innovative Efficient Infeed Technology is employed in PM250 Power Modules. This technology allows the energy produced by motors operating in generator mode connected to standard inverters to be fed back into the supply system. For control cabinets, an additional temperature rise can be avoided and the amount of space required can be reduced due to the fact that components such as braking resistors, braking choppers and line reactors can be eliminated. Further, wiring and engineering costs are significantly reduced. At the same time, energy consumption can be reduced and ongoing operating costs noticeably reduced.
Additional inbation is provided in chapter Highlights, section Efficient Infeed Technology.
Innovative cooling concept and varnishing of electronic modules
The new cooling system and varnishing of the electronic modules significantly increases the service life or useful life of the device.
-
Disposal of all heat losses via an external heat sink
-
Consequential convection cooling of the Control Unit, electronic modules are not located in the air duct
-
All cooling air from the fan is directed through the heat sink
Energy efficiency
Integrated technologies help when optimizing the energy usage of the plant or system referred to the particular application:
-
Energy-efficient vector control with or without sensors
-
Automatic flux reduction with U/f ECO mode
-
Integrated energy saving computer
Additional inbation is provided in chapter Highlights, section Energy efficiency.
Application-orientated design of SINAMICS G120
SINAMICS G120 standard inverters are modular inverters for standard drives. Selection of the SINAMICS G120 is reduced to two or three steps thanks to the modular system used.
Selecting the Control Unit
The optimum Control Unit is selected first, based on the number of I/Os and any additional functions required such as Safety Integrated or HVAC. The communication options are already integrated and do not have to be additionally ordered or plugged in. Three product series are available corresponding to the particular application.
CU230P‑2 Control Units
The CU230P‑2 Control Units have been specifically designed for pump, fan and compressor applications.
The CU230P‑2 is the Control Unit for the pump, fan and compressor inverters SINAMICS G120P and SINAMICS G120P Cabinet. Detailed inbation can be found in Catalog D 35.
Control Unit CU240E‑2
The CU240E‑2 Control Unit is suitable for a wide range of applications in general machine construction, such as conveyor belts, mixers and extruders.
CU250S‑2 Control Units
The CU250S‑2 Control Units are suitable for applications involving single drives with exacting speed control requirements such as extruders and centrifuges, and for bing tasks such as conveyor belts, lifting/lowering devices, etc. They can also be used to implement multi-motor drives without DC coupling such as wire-drawing machines and simple material lines.
Debion
|
Fieldbus
|
Profile
|
Inputs
Outputs
|
Integrated safety technology
|
Fail-safe
digital bs
digital outputs
|
Control Unit
|
|
|
|
|
|
|
Article No.
|
CU230P‑2 series - the specialist for pumps, fans, compressors, water, buildings
Technology functions (selection): Free function blocks (FFB), 4 × PID controller, cascade connection, hibernation mode, essential service mode, multi-zone control
|
CU230P‑2 HVAC
|
-
USS
-
Modbus RTU
-
BACnet MS/TP
-
FLN P1
|
–
|
6 DI
4 AI
3 DO
2 AO
|
–
|
–
|
6SL3243-0BB30-1HA3
|
CU230P‑2 DP
|
|
|
6SL3243-0BB30-1PA3
|
CU230P‑2 PN
|
|
|
6SL3243-0BB30-1FA0
|
-
ODVA AC drive
-
SINAMICS profile
|
–
|
CU240E‑2 series – for standard applications in general machinery construction, such as conveyor belts, mixers and extruders – without encoder
Technology functions (selection): Free function blocks (FFB), 1 × PID controller, motor holding brake
|
CU240E‑2
|
|
–
|
6 DI
2 AI
3 DO
2 AO
|
STO
|
1 F-DI
(opt. for each 2 DI)
|
6SL3244-0BB12-1BA1
|
CU240E‑2 DP
|
|
|
6SL3244-0BB12-1PA1
|
CU240E‑2 PN
|
|
-
PROFIdrive
-
PROFIsafe
-
PROFIenergy
|
6SL3244-0BB12-1FA0
|
-
ODVA AC drive
-
SINAMICS profile
|
–
|
CU240E‑2 F
|
|
–
|
STO, SS1, SLS, SDI
|
3 F-DI
(opt. for each 2 DI)
|
6SL3244-0BB13-1BA1
|
CU240E‑2 DP‑F
|
|
|
STO, SS1, SLS, SSM 1), SDI
|
6SL3244-0BB13-1PA1
|
CU240E‑2 PN‑F
|
|
-
PROFIdrive
-
PROFIsafe
-
PROFIenergy
|
6SL3244-0BB13-1FA0
|
-
ODVA AC drive
-
SINAMICS profile
|
–
|
CU250S‑2 series – for complex applications such as extruders and centrifuges – with and without encoder (basic ber (EPos) optional)
Technology functions (selection): Free function blocks (FFB), 1 × PID controller, motor holding brake
|
CU250S‑2
|
|
–
|
11 DI
2 AI
3 DO
2 AO
4 DI/DO (DI can be used as high-speed bs)
|
STO, SBC, SS1
|
3 F-DI
(opt. for each 2 DI)
1 F-DO
(opt. for each 2 DO)
|
6SL3246-0BA22-1BA0
|
CU250S‑2 DP
|
|
|
6SL3246-0BA22-1PA0
|
CU250S‑2 PN
|
|
-
PROFIdrive
-
PROFIsafe
-
PROFIenergy
|
6SL3246-0BA22-1FA0
|
-
ODVA AC drive
-
SINAMICS profile
|
–
|
CU250S‑2 CAN
|
|
–
|
6SL3246-0BA22-1CA0
|
1) SSM is possible only with PROFIsafe.
Optional memory card with firmware V4.7 SP6 for CU230P‑2, CU240E‑2 and CU250S‑2 Control Units
Debion
|
Suitable for
|
Article No.
|
SINAMICS SD card
512 MB + firmware V4.7 SP6 (Multicard V4.7 SP6)
|
CU230P‑2
CU240E‑2
CU250S‑2
|
6SL3054-7TD00-2BA0
|
Optional memory cards with licenses for CU250S‑2 Control Units only
Debion
|
SINAMICS SD card
512 MB + licenses
|
SINAMICS SD card
512 MB + firmware V4.7 SP6 (Multicard V4.7 SP6) + licenses
|
Licenses (without SD card)
for upgrading license
of an existing SD card
|
|
Article No.
|
Article No.
|
Article No.
|
License Extended Functions
Basic ber (EPos)
|
6SL3054-4AG00-2AA0-Z
E01
|
6SL3054-7TD00-2BA0-Z
E01
|
6SL3074-7AA04-0AA0
|
License Extended Functions
Safety (SLS, SSM, SDI)
|
6SL3054-4AG00-2AA0-Z
F01
|
6SL3054-7TD00-2BA0-Z
F01
|
6SL3074-0AA10-0AA0
|
Licenses Extended Functions
Basic ber (EPos) + Safety (SLS, SSM, SDI)
|
6SL3054-4AG00-2AA0-Z
E01+F01
|
6SL3054-7TD00-2BA0-Z
E01+F01
|
–
|
For additional inbation about firmware V4.7 SP6:
https://support.industry.siemens.com/cs/document/109482094
Optional memory cards with firmware V4.6 or V4.7 for existing installations when service is required
Debion
|
Suitable for
|
Article No.
|
SINAMICS SD card
512 MB + firmware V4.6 (Multicard V4.6)
|