----上海诗幕自动化设备有限公司
|
PROFINET:A 型 |
PROFINET:B 型: |
PROFINET:型号 C |
|
---|---|---|---|
AWG 22/1 |
适合偶然移动的 AWG 22/7 柔性电缆 |
AWG 22 |
|
IE FC TP 标准电缆 GP 2 x 2 |
❑ |
– |
– |
IE FC TP 标准电缆 GP 2 x 2(A 型)6XV1841-2A |
❑ |
– |
– |
IE FC TP 软电缆 GP2 x 2 |
– |
❑ |
– |
IE FC TP 耐用型软电缆 GP 2x2:(B 型)6XV1841-2B |
– |
❑ |
– |
IE FC TP FRNC 电缆 GP 2 x 2 |
– |
❑ |
– |
IE FC TP 拖缆 GP 2 x 2 |
– |
– |
❑ |
IE FC TP 拖缆 2 x 2 |
– |
– |
❑ |
IE FC TP 彩色电缆 GP 2 x 2 (B 型) |
– |
❑ |
– |
IE TP 扭转电缆 2 x 2 |
– |
- |
❑ |
IE FC TP 食品级电缆 |
– |
- |
❑ |
IE FC TP 耐用型食品级电缆 |
– |
❑ |
– |
IE FC TP 船用电缆 2 x 2 |
– |
❑ |
- |
IE TP 接地电缆 2 x 2 |
– |
– |
❑ |
IE TP 铁路电缆 2 x 2 |
– |
– |
❑ |
1) 可通过以下网址下载:
http://www.profinet.com
Article number |
6XV1840-2AH10 |
6XV1841-2A |
6XV1870-2B |
6XV1841-2B |
|
---|---|---|---|---|---|
Product type designation |
IE FC TP Standard Cable GP 2 x 2 (Type A) |
IE FC TP Robust Standard Cable GP 2 x 2 (Type A) |
IE FC TP Flexible Cable GP 2 x 2 (Type B) |
IE FC TP Robust Flexible Cable GP 2 x 2 (Type B) |
|
Product debion |
Standard bus cable (4-core), sold by the meter, unassembled |
Standard bus cable (4-core), sold by the meter, unassembled |
Flexible bus cable (4-core), sold by the meter, unassembled |
Flexible bus cable (4-core), sold by the meter, unassembled |
|
Suitability for use |
Standard cable with rigid cores for fast installation |
Standard cable with rigid cores for fast installation |
For occasionally moved machine parts |
For occasionally moved machine parts |
|
Cable designation |
2YY (ST) CY 2x2x0,64/1,5-100 GN SF/UTP |
2YH (ST) C99Y 2x2x0,64/1,5-100 GN SF/UTP |
2YY (ST) CY 2x2x0,75/1,5-100 LI GN SF/UTP |
2YH (ST) C99Y 2x2x0,75/1,5-100 LI GN SF/UTP |
|
Electrical data |
|
|
|
|
|
Damping ratio per length |
|
|
|
|
|
|
52 dB/km |
65 dB/km |
60 dB/km |
65 dB/km |
|
|
195 dB/km |
220 dB/km |
210 dB/km |
220 dB/km |
|
Impedance |
|
|
|
|
|
|
100 Ω |
100 Ω |
100 Ω |
100 Ω |
|
Relative symmetrical tolerance |
|
|
|
|
|
|
15 % |
15 % |
15 % |
15 % |
|
Near-end crosstalk per length |
|
|
|
|
|
|
500 dB/km |
500 dB/km |
500 dB/km |
500 dB/km |
|
Transfer impedance per length at 10 MHz |
10 mΩ/m |
10 mΩ/m |
20 mΩ/m |
20 mΩ/m |
|
Loop resistance per length maximum |
115 mΩ/m |
115 mΩ/m |
120 mΩ/m |
120 mΩ/m |
|
Operating voltage |
|
|
|
|
|
|
80 V |
80 V |
80 V |
80 V |
|
NVP value in percent |
66 % |
66 % |
66 % |
66 % |
|
Mechanical data |
|
|
|
|
|
Number of electrical cores |
4 |
4 |
4 |
4 |
|
Design of the shield |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
|
Type of electrical connection FastConnect |
Yes |
Yes |
Yes |
Yes |
|
Core diameter |
|
|
|
|
|
|
0.64 mm |
0.64 mm |
0.75 mm |
0.75 mm |
|
Outer diameter |
|
|
|
|
|
|
0.64 mm |
0.64 mm |
0.75 mm |
0.75 mm |
|
|
1.5 mm |
1.5 mm |
1.5 mm |
1.5 mm |
|
|
3.9 mm |
3.9 mm |
3.9 mm |
3.9 mm |
|
|
6.5 mm |
6.5 mm |
6.5 mm |
6.5 mm |
|
Symmetrical tolerance of the outer diameter of cable sheath |
0.2 mm |
0.2 mm |
0.2 mm |
0.2 mm |
|
Material |
|
|
|
|
|
|
PE |
PE |
PE |
PE |
|
|
PVC |
FRNC |
PVC |
FRNC |
|
|
PVC |
TPE (FR-TPE) |
PVC |
TPE (FR-TPE) |
|
Color |
|
|
|
|
|
|
white/yellow/blue/orange |
white/yellow/blue/orange |
white/yellow/blue/orange |
white/yellow/blue/orange |
|
|
green |
green |
green |
green |
|
Bending radius |
|
|
|
|
|
|
19.5 mm |
26 mm |
32.5 mm |
32.5 mm |
|
|
49 mm |
52 mm |
52 mm |
52 mm |
|
Tensile load maximum |
150 N |
150 N |
150 N |
150 N |
|
Weight per length |
67 kg/km |
59 kg/km |
68 kg/km |
68 kg/km |
|
Permitted ambient conditions |
|
|
|
|
|
Ambient temperature |
|
|
|
|
|
|
-40 ... +75 °C |
-40 ... +75 °C |
-25 ... +75 °C |
-40 ... +75 °C |
|
|
-40 ... +75 °C |
-40 ... +75 °C |
-25 ... +75 °C |
-40 ... +75 °C |
|
|
-40 ... +75 °C |
-40 ... +75 °C |
-25 ... +75 °C |
-40 ... +75 °C |
|
|
-20 ... +60 °C |
-20 ... +60 °C |
-10 ... +60 °C |
-20 ... +60 °C |
|
|
Electrical properties measured at 20 °C, tests according to DIN VDE 0472 |
Electrical properties measured at 20 °C, tests according to DIN VDE 0472 |
Electrical properties measured at 20 °C, tests according to DIN VDE 0472 |
Electrical properties measured at 20 °C, tests according to DIN VDE 0472 |
|
Burning behavior |
flame resistant according to UL 1685 (CSA FT 4) |
flame resistant according to IEC 60332-1-2 |
flame resistant according to UL 1685 (CSA FT 4) |
flame resistant according to IEC 60332-1-2 |
|
Chemical resistance |
|
|
|
|
|
|
oil resistant according to IEC 60811-2-1 (4 h / 70°C) |
oil resistant according to DIN EN 50290-2-22 (VDE 0819), (7x24h/90°C), UL13 Sec.40 (96h/100°C) |
oil resistant according to IEC 60811-404 (7x24h/90°C) |
oil resistant according to DIN EN 50290-2-22 (VDE 0819), (7x24h/90°C), UL13 Sec.40 (96h/100°C) |
|
|
Conditional resistance |
Conditional resistance |
Conditional resistance |
Conditional resistance |
|
|
conditional resistance |
conditional resistance |
conditional resistance |
conditional resistance |
|
Radiological resistance to UV radiation |
resistant |
resistant |
resistant |
resistant |
|
Product properties, functions, components general |
|
|
|
|
|
Product feature |
|
|
|
|
|
|
No |
No |
No |
No |
|
|
Yes |
Yes |
Yes |
Yes |
|
Wire length for Industrial Ethernet |
|
|
|
|
|
|
100 m |
100 m |
85 m |
85 m |
|
Standards, specifications, approvals |
|
|
|
|
|
UL/ETL listing 300 V Rating |
Yes; cULus / CMG / PLTC/ ITC(UL) / Sun Res |
Yes; c(ETL)us, CM, PLTC, SUN RES |
Yes; c(UL)us, CMG / PLTC / Sun Res / OIL RES |
Yes; c(ETL)us, CM, PLTC, SUN RES |
|
UL/ETL style 600 V Rating |
Yes |
No |
No |
No |
|
Certificate of suitability |
|||||
|
Yes |
Yes |
Yes |
Yes |
|
|
Yes |
Yes |
Yes |
Yes |
|
Standard for structured cabling |
Cat5e |
Cat5e |
Cat5e |
Cat5e |
|
Marine classification association |
|
|
|
|
|
|
No |
No |
No |
No |
|
|
No |
No |
No |
No |
|
|
No |
No |
No |
No |
|
|
No |
No |
No |
No |
|
|
No |
No |
No |
No |
|
|
No |
No |
No |
No |
|
|
No |
No |
No |
No |
Article number |
6XV1870-2F |
6XV1870-2D |
6XV1840-3AH10 |
6XV1871-2S |
|
---|---|---|---|---|---|
Product type designation |
IE TP Torsion Cable 2 x 2 (Type C) |
IE FC TP Trailing Cable GP 2 x 2 (Type C) |
IE FC TP Trailing Cable 2 x 2 (Type C) |
IE FC TP Festoon Cable GP 2 x 2 (Type B) |
|
Product debion |
Highly flexible bus cable (4-core), sold by the meter, unassembled |
Highly flexible bus cable (4-core), sold by the meter, unassembled |
Highly flexible bus cable (4-core), sold by the meter, unassembled |
Flexible bus cable (4-core), sold by the meter, unassembled |
|
Suitability for use |
Continuous motion control when using robots |
Continuous motion control in a cable carrier |
Continuous motion control in a cable carrier |
For continuous motion in a trailing cable, festoon mounting |
|
Cable designation |
02YS C11Y 1x4x0,75/1,5-100 LI VZN FRNC GN SF/UTP |
2YY (ST) CY 2x2x0,75/1,5-100 LI GN SF/UTP |
2YH (ST) C11Y 2x2x0,75/1,5-100 LI GN VZN FRNC SF/UTP |
2YY (ST) CY 2x2x0,75/1,5 LI GN SF/UTP |
|
Electrical data |
|
|
|
|
|
Damping ratio per length |
|
|
|
|
|
|
81 dB/km |
63 dB/km |
60 dB/km |
63 dB/km |
|
|
410 dB/km |
213 dB/km |
220 dB/km |
213 dB/km |
|
Impedance |
|
|
|
|
|
|
100 Ω |
100 Ω |
100 Ω |
100 Ω |
|
Relative symmetrical tolerance |
|
|
|
|
|
|
15 % |
5 % |
15 % |
5 % |
|
Near-end crosstalk per length |
|
|
|
|
|
|
500 dB/km |
500 dB/km |
500 dB/km |
500 dB/km |
|
Transfer impedance per length at 10 MHz |
100 mΩ/m |
20 mΩ/m |
10 mΩ/m |
100 mΩ/m |
|
Loop resistance per length maximum |
120 mΩ/m |
120 mΩ/m |
120 mΩ/m |
120 mΩ/m |
|
Operating voltage |
|
|
|
|
|
|
80 V |
80 V |
80 V |
80 V |
|
NVP value in percent |
70 % |
66 % |
66 % |
66 % |
|
Mechanical data |
|
|
|
|
|
Number of electrical cores |
4 |
4 |
4 |
4 |
|
Design of the shield |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
|
Type of electrical connection FastConnect |
No |
Yes |
Yes |
Yes |
|
Core diameter |
|
|
|
|
|
|
0.76 mm |
0.75 mm |
0.75 mm |
0.75 mm |
|
Outer diameter |
|
|
|
|
|
|
0.76 mm |
0.75 mm |
0.75 mm |
0.75 mm |
|
|
1.5 mm |
1.5 mm |
1.5 mm |
1.5 mm |
|
|
3.9 mm |
3.9 mm |
3.9 mm |
||
|
6.5 mm |
6.5 mm |
6.5 mm |
6.5 mm |
|
Symmetrical tolerance of the outer diameter of cable sheath |
0.2 mm |
0.2 mm |
0.2 mm |
0.2 mm |
|
Material |
|
|
|
|
|
|
PE |
PE |
PE |
PE |
|
|
PVC |
FRNC |
PVC |
||
|
PUR (TPE-U) |
PVC |
PUR (TPE-U) |
PVC |
|
Color |
|
|
|
|
|
|
white/yellow/blue/orange |
white/yellow/blue/orange |
white/yellow/blue/orange |
white/yellow/blue/orange |
|
|
green |
green |
green |
green |
|
Bending radius |
|
|
|
|
|
|
32.5 mm |
32.5 mm |
19.5 mm |
30 mm |
|
|
65 mm |
49 mm |
49 mm |
70 mm |
|
|
100 mm |
100 mm |
70 mm |
||
Number of bending cycles |
Not suitable for garland usage |
3 000 000; Drag chain suitable for 3 million bending cycles at a bending radius of 100 mm, a speed of 4 m/s and an acceleration of 4 m/s² |
4 000 000; Drag chain suitable for 4 million bending cycles at a bending radius of 100 mm, a speed of 4 m/s and an acceleration of 4 m/s² |
5 000 000; 5 million bending cycles at a bending radius of 70 mm and an acceleration of 4 m/s² |
|
Number of torsion cycles with torsion by ± 180° on 1 m cable length |
5 000 000 |
||||
Tensile load maximum |
130 N |
150 N |
150 N |
150 N |
|
Weight per length |
54 kg/km |
68 kg/km |
63 kg/km |
68 kg/km |
|
Permitted ambient conditions |
|
|
|
|
|
Ambient temperature |
|
|
|
|
|
|
-40 ... +80 °C |
-25 ... +75 °C |
-40 ... +75 °C |
-40 ... +75 °C |
|
|
-40 ... +80 °C |
-25 ... +75 °C |
-50 ... +75 °C |
-50 ... +75 °C |
|
|
-40 ... +80 °C |
-25 ... +75 °C |
-50 ... +75 °C |
-50 ... +75 °C |
|
|
-20 ... +60 °C |
-10 ... +60 °C |
-20 ... +60 °C |
-20 ... +60 °C |
|
|
Electrical properties measured at 20 °C, tests according to DIN VDE 0472 |
Electrical properties measured at 20 °C, tests according to DIN VDE 0472 |
Electrical properties measured at 20 °C, tests according to DIN VDE 0472 |
Electrical properties measured at 20 °C, tests according to DIN VDE 0472 |
|
Burning behavior |
flame resistant according to IEC 60332-1-2 |
flame resistant according to UL 1685 (CSA FT 4) |
flame resistant according to IEC 60332-1-2 |
flame resistant according to UL 1685 (CSA FT 4) |
|
Chemical resistance |
|
|
|
|
|
|
oil resistant according to IEC 60811-2-1 (7x24h/90°C) |
oil resistant according to IEC 60811-404 (7x24h/90°C) |
oil resistant according to IEC 60811-2-1 (7x24h/90°C) |
conditional resistance |
|
|
resistant |
Conditional resistance |
resistant |
Conditional resistance |
|
|
resistant |
conditional resistance |
resistant |
conditional resistance |
|
Radiological resistance to UV radiation |
resistant |
resistant |
resistant |
resistant |
|
Product properties, functions, components general |
|
|
|
|
|
Product feature |
|
|
|
|
|
|
Yes |
No |
Yes |
No |
|
|
Yes |
Yes |
Yes |
Yes |
|
Wire length for Industrial Ethernet |
|
|
|
|
|
|
75 m |
85 m |
85 m |
85 m |
|
Standards, specifications, approvals |
|
|
|
|
|
UL/ETL listing 300 V Rating |
Yes; UL Style 21161 |
Yes; c(UL)us, CMG / PLTC / Sun Res / OIL RES |
Yes; cULus / CMX |
Yes; c(UL)us, CMG / PLTC / Sun Res / OIL RES |
|
UL/ETL style 600 V Rating |
No |
Yes |
No |
Yes |
|
Certificate of suitability |
|||||
|
Yes |
Yes |
Yes |
Yes |
|
|
Yes |
Yes |
Yes |
Yes |
|
Standard for structured cabling |
Cat5e |
Cat5e |
Cat5e |
Cat5e |
|
Marine classification association |
|
|
|
|
|
|
No |
No |
No |
No |
|
|
No |
No |
No |
No |
|
|
No |
No |
No |
No |
|
|
No |
No |
No |
No |
|
|
No |
No |
No |
No |
|
|
No |
No |
No |
No |
|
|
No |
No |
No |
No |
Article number |
6XV1871-2F |
6XV1871-2L |
6XV1881-2A |
6XV1840-4AH10 |
|
---|---|---|---|---|---|
Product type designation |
IE FC TP FRNC Cable GP 2x2 (Type B) |
IE FC TP Food Cable 2 x 2 (Type C) |
IE FC TP Robust Food Cable GP 2X2 (Typ B) |
IE FC TP Marine Cable 2 x 2 (Type B) |
|
Product debion |
Flexible halogen-free bus cable acc. to IEC 60754-1/2 (4-core), sold by the meter, unassembled |
Flexible bus cable (4-core), sold by the meter, unassembled |
Robust, flexible bus cable (4-core), sold by the meter, unassembled |
Halogen-free bus cable acc. to IEC 60754-1/2 (4-core), sold by the meter, unassembled |
|
Suitability for use |
For occasionally moved machine parts |
Food and beverages industry |
For marine and offshore use |
||
Cable designation |
L-9YH (ST) CH 2x2x0,34/1,5-100 GN VZN FRNC SF/UTP |
2YH (ST) C2Y 2X2X0,75/1,5-100 LI SF/UTP |
2YY(ST)CY6Y 2X2X0.75/1.55 LI VZN |
L-9YH (ST) CH 2 x 2 x 0,34/1,5-100 GN VZN FRNC SF/UTP |
|
Electrical data |
|
|
|
|
|
Damping ratio per length |
|
|
|
|
|
|
60 dB/km |
63 dB/km |
95 dB/km |
60 dB/km |
|
|
220 dB/km |
213 dB/km |
320 dB/km |
220 dB/km |
|
Impedance |
|
|
|
|
|
|
100 Ω |
100 Ω |
100 Ω |
100 Ω |
|
Relative symmetrical tolerance |
|
|
|
|
|
|
15 % |
5 % |
5 % |
15 % |
|
Near-end crosstalk per length |
|
|
|
|
|
|
0.5 dB/m |
0.5 dB/m |
0.353 dB/m |
0.5 dB/m |
|
Transfer impedance per length at 10 MHz |
10 mΩ/m |
10 mΩ/m |
80 mΩ/m |
10 mΩ/m |
|
Loop resistance per length maximum |
120 mΩ/m |
120 mΩ/m |
120 mΩ/m |
120 mΩ/m |
|
Operating voltage |
|
|
|
|
|
|
80 V |
80 V |
80 V |
80 V |
|
NVP value in percent |
66 % |
66 % |
63 % |
66 % |
|
Mechanical data |
|
|
|
|
|
Number of electrical cores |
4 |
4 |
4 |
4 |
|
Design of the shield |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
|
Type of electrical connection FastConnect |
Yes |
Yes |
Yes |
Yes |
|
Core diameter |
|
|
|
|
|
|
0.75 mm |
0.75 mm |
0.75 mm |
0.75 mm |
|
Outer diameter |
|
|
|
|
|
|
0.75 mm |
0.75 mm |
0.75 mm |
0.75 mm |
|
|
1.5 mm |
1.5 mm |
1.56 mm |
1.5 mm |
|
|
3.9 mm |
3.9 mm |
4 mm |
3.9 mm |
|
|
6.5 mm |
6.5 mm |
6.5 mm |
6.5 mm |
|
Symmetrical tolerance of the outer diameter of cable sheath |
0.2 mm |
0.2 mm |
0.2 mm |
0.2 mm |
|
Material |
|
|
|
|
|
|
PP |
PE |
PE |
PP |
|
|
FRNC |
FRNC |
PVC |
FRNC |
|
|
FRNC |
PE |
PVC/FEP; FEP transparent |
FRNC |
|
Color |
|
|
|
|
|
|
white/yellow/blue/orange |
white/yellow/blue/orange |
white/yellow/blue/orange |
white/yellow/blue/orange |
|
|
green |
Black |
green |
green |
|
Bending radius |
|
|
|
|
|
|
39 mm |
20 mm |
26 mm |
39 mm |
|
|
97.5 mm |
49 mm |
52 mm |
97.5 mm |
|
|
100 mm |
||||
Number of bending cycles |
500 000; Acceleration 4 m/s² |
||||
Number of torsion cycles with torsion by ± 180° on 1 m cable length |
1 000 000 |
||||
Tensile load maximum |
150 N |
150 N |
150 N |
150 N |
|
Weight per length |
68 kg/km |
55 kg/km |
72 kg/km |
68 kg/km |
|
Permitted ambient conditions |
|
|
|
|
|
Ambient temperature |
|
|
|
|
|
|
-25 ... +70 °C |
-40 ... +75 °C |
-40 ... +80 °C |
-25 ... +70 °C |
|
|
-40 ... +75 °C |
-50 ... +75 °C |
-40 ... +80 °C |
-40 ... +85 °C |
|
|
-40 ... +75 °C |
-50 ... +75 °C |
-40 ... +80 °C |
-40 ... +85 °C |
|
|
0 ... 50 °C |
-20 ... +60 °C |
-40 ... +80 °C |
0 ... 50 °C |
|
|
Electrical properties measured at 20 °C, tests according to DIN VDE 0472 |
Electrical properties measured at 20 °C, tests according to DIN VDE 0472 |
Electrical properties measured at 20 °C, tests according to DIN VDE 0472 |
Electrical properties measured at 20 °C, tests according to DIN VDE 0472 |
|
Ambient condition for operation |
Temperature range for permanent installation -40 °C to 85 °C |
||||
Burning behavior |
flame resistant according to IEC 60332-3-22 (Category A/F), IEC 61034 |
inflammable |
flame resistant according to IEC 60332-1-2 |
flame resistant according to IEC 60332-3-22 (Category A/F), smoke density according to IEC 61034-1/2 |
|
Chemical resistance |
|
|
|
|
|
|
oil resistant according to IEC 60811-2-1 (4 h / 70°C) |
oil resistant according to IEC 60811-2-1 (4 h / 70°C) |
oil resistant according to IEC 60811-404 (7x24 h / 90°C) |
conditional resistance, IEC 60811-2-1 (4 hours / 70 °C) |
|
|
Conditional resistance |
Conditional resistance |
Conditional resistance |
Conditional resistance |
|
|
conditional resistance |
conditional resistance |
resistant |
conditional resistance |
|
Radiological resistance to UV radiation |
resistant |
resistant |
resistant |
resistant |
|
Product properties, functions, components general |
|
|
|
|
|
Product feature |
|
|
|
|
|
|
Yes |
Yes |
No |
Yes |
|
|
Yes |
Yes |
Yes |
Yes |
|
Wire length for Industrial Ethernet |
|
|
|
|
|
|
85 m |
85 m |
85 m |
85 m |
|
Standards, specifications, approvals |
|
|
|
|
|
UL/ETL listing 300 V Rating |
Yes; c(UL)us, CMG / PLTC / Sun Res / OIL RES |
No |
Yes; c(ETL)us, CMG, (ETL)us PLTC-ER, SUN RES, OIL RES 1 |
Yes; cULus / CMG / PLTC / Sun Res |
|
UL/ETL style 600 V Rating |
No |
No |
No |
No |
|
Certificate of suitability |
|||||
|
Yes |
Yes |
Yes |
Yes |
|
|
Yes |
Yes |
Yes |
Yes |
|
|
EHEDG, Installation and layout of the cables must fulfil the requirements of EHEDG published in the Guidelines Doc. 13 'Hygienic Design of open equipment for processing food' and Doc. 44 'Hygienic Design Principles for food factories' to be accessible for cleaning. Also connections must be easily cleanable by using EHEDG certified cable glands or connectors. |
||||
Standard for structured cabling |
Cat5e |
Cat5e |
Cat5e |
Cat5e |
|
Marine classification association |
|
|
|
|
|
|
No |
No |
No |
Yes |
|
|
No |
No |
No |
Yes |
|
|
No |
No |
No |
Yes |
|
|
No |
No |
No |
Yes |
|
|
No |
No |
No |
Yes |
|
|
No |
No |
No |
No |
|
|
No |
No |
No |
No |
Article number |
6XV1871-2G |
6XV1871-2T |
|
---|---|---|---|
Product type designation |
IE TP Ground Cable 2x2 (Type C) |
IE TP Train Cable 2x2 (Type C, AWG22/7) |
|
Product debion |
Standard bus cable (4-core), for laying underground, sold by the meter, unassembled |
Flexible bus cable with tinned copper leads (4-core) for rail applications, sold by the meter, unassembled |
|
Suitability for use |
Standard cable with rigid cores for fast installation |
For laying in rail vehicles and buses |
|
Cable designation |
2YY(ST)CY2Y2x2x0.64/1.50-100 SF/UTP |
SF/UTP |
|
Electrical data |
|
|
|
Damping ratio per length |
|
|
|
|
63 dB/km |
53 dB/km |
|
|
213 dB/km |
188 dB/km |
|
Impedance |
|
|
|
|
100 Ω |
100 Ω |
|
Relative symmetrical tolerance |
|
|
|
|
5 % |
5 % |
|
Near-end crosstalk per length |
|
|
|
|
500 dB/km |
500 dB/km |
|
Transfer impedance per length at 10 MHz |
10 mΩ/m |
8 mΩ/m |
|
Loop resistance per length maximum |
124 mΩ/m |
124 mΩ/m |
|
Operating voltage |
|
|
|
|
100 V |
125 V |
|
NVP value in percent |
64 % |
||
Mechanical data |
|
|
|
Number of electrical cores |
4 |
4 |
|
Design of the shield |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
|
Type of electrical connection FastConnect |
Yes |
No |
|
Core diameter |
|
|
|
|
0.64 mm |
0.75 mm |
|
Outer diameter |
|
|
|
|
0.64 mm |
0.75 mm |
|
|
1.5 mm |
1.5 mm |
|
|
4 mm |
||
|
9 mm |
6.6 mm |
|
|
Cable diameter >6.5 mm because of additional PE outer cover. Cable can only be connected to RJ45/M12 connector after outer cover is removed. |
||
Symmetrical tolerance of the outer diameter of cable sheath |
0.2 mm |
0.2 mm |
|
Material |
|
|
|
|
PE |
PE |
|
|
PVC |
||
|
PVC |
Elastomer meshed electron beam |
|
Color |
|
|
|
|
white/yellow/blue/orange |
white/yellow/blue/orange |
|
|
Black |
Black |
|
Bending radius |
|
|
|
|
80 mm |
40 mm |
|
|
80 mm |
40 mm |
|
Tensile load maximum |
150 N |
150 N |
|
Weight per length |
97 kg/km |
71 kg/km |
|
Permitted ambient conditions |
|
|
|
Ambient temperature |
|
|
|
|
-40 ... +70 °C |
-40 ... +80 °C |
|
|
-40 ... +70 °C |
-40 ... +80 °C |
|
|
-40 ... +70 °C |
-40 ... +80 °C |
|
|
-5 ... +50 °C |
-20 ... +60 °C |
|
|
Electrical properties measured at 20 °C, tests according to EN50288-2-1 |
For a short duration in case of short-circuit fault 160°C |
|
Ambient condition for operation |
Electrical characteristics measured at 20 ºC, tests according to EN50288-2-1 |
||
Burning behavior |
inflammable |
BS6853, DIN5510-2 Brandschutzstufe 1-4, prEN45545-2 Hazard Level HL1-HL3, EN50306-4, NF F 16-101, NFPA130 |
|
Chemical resistance |
|
|
|
|
conditional resistance |
EN 50306-4 (72h/100 °C, IRM 902, 168h/70 °C, IRM 903) |
|
|
Conditional resistance |
Conditional resistance |
|
|
Resistant |
conditional resistance |
|
Radiological resistance to UV radiation |
resistant |
resistant |
|
Product properties, functions, components general |
|
|
|
Product feature |
|
|
|
|
No |
Yes |
|
|
Yes |
Yes |
|
Wire length for Industrial Ethernet |
|
|
|
|
100 m |
100 m |
|
Standards, specifications, approvals |
|
|
|
UL/ETL listing 300 V Rating |
No |
No |
|
UL/ETL style 600 V Rating |
No |
No |
|
Certificate of suitability |
|||
|
Yes |
Yes |
|
|
Yes |
Yes |
|
Standard for structured cabling |
Cat5e |
Cat5 |
|
Marine classification association |
|
|
|
|
No |
No |
|
|
No |
No |
|
|
No |
No |
|
|
No |
No |
|
|
No |
No |
|
|
No |
No |
|
|
No |
No |
安装说明
总线电缆按米销售,带有印刷标记。
快速连接
用工业以太网快速连接剥线工具,能在一次操作中就可将新的工业以太网快速连接电缆 2 x 2 的外皮和屏蔽层剥离到正确的长度。 IE 引出插座 RJ45 和 PROFINET 兼容插塞接头 IE FC RJ45 接头可快速、方便地连接到工业以太网快速连接电缆 2 x 2。
电缆布线
在贮存、运输和电缆敷设过程中,应使用热压帽封住电缆的每一端;不要超过允许的弯曲半径和拉伸应力。
概述
优势
应用为不同的应用类型提供有不同类型的电缆,以配置工业以太网(4 芯)。 一般来说,应使用所列出的工业以太网 FC IE FC 电缆 2 x 2。
注意: UL 认证 通过相应 UL 认证的不同型号的电缆,可安装在电缆束和电缆架中,符合 NEC/ETL 标准 Article 800/725。并标识有“GP(通用)”字样。 设计FastConnect (FC) 工业以太网 IE FC 电缆 2 x 2 为径向对称结构设计,可采用 FC 剥线工具,从而可快速、简便地装配 IE FC 接口 RJ45 和 IE FC 接头。
电缆类型
产品概述 IE FC电缆 2 x 2(与 PROFINET 兼容,符合“PROFINET 电缆布线和互连技术指南”1))
1) 可通过以下网址下载: 技术规范
更多信息安装说明 总线电缆按米销售,带有印刷标记。 快速连接 用工业以太网快速连接剥线工具,能在一次操作中就可将新的工业以太网快速连接电缆 2 x 2 的外皮和屏蔽层剥离到正确的长度。 IE 引出插座 RJ45 和 PROFINET 兼容插塞接头 IE FC RJ45 接头可快速、方便地连接到工业以太网快速连接电缆 2 x 2。 电缆布线 在贮存、运输和电缆敷设过程中,应使用热压帽封住电缆的每一端;不要超过允许的弯曲半径和拉伸应力。 |
|
概述
优势
应用为不同的应用类型提供有不同类型的电缆,以配置工业以太网(4 芯)。 一般来说,应使用所列出的工业以太网 FC IE FC 电缆 2 x 2。
注意: UL 认证 通过相应 UL 认证的不同型号的电缆,可安装在电缆束和电缆架中,符合 NEC/ETL 标准 Article 800/725。并标识有“GP(通用)”字样。 设计FastConnect (FC) 工业以太网 IE FC 电缆 2 x 2 为径向对称结构设计,可采用 FC 剥线工具,从而可快速、简便地装配 IE FC 接口 RJ45 和 IE FC 接头。
电缆类型
产品概述 IE FC电缆 2 x 2(与 PROFINET 兼容,符合“PROFINET 电缆布线和互连技术指南”1))
1) 可通过以下网址下载: 技术规范
更多信息安装说明 总线电缆按米销售,带有印刷标记。 快速连接 用工业以太网快速连接剥线工具,能在一次操作中就可将新的工业以太网快速连接电缆 2 x 2 的外皮和屏蔽层剥离到正确的长度。 IE 引出插座 RJ45 和 PROFINET 兼容插塞接头 IE FC RJ45 接头可快速、方便地连接到工业以太网快速连接电缆 2 x 2。 电缆布线 在贮存、运输和电缆敷设过程中,应使用热压帽封住电缆的每一端;不要超过允许的弯曲半径和拉伸应力。 |
|