6ES7141-4BF00-0AA0西门子电子模块现货 6ES7141-4BF00-0AA0西门子电子模块现货 6ES7141-4BF00-0AA0西门子电子模块现货
6ES7141-4BF00-0AA0
6ES7141-4BF00-0AA0
SIMATIC DP, ET 200 PRO 的电子模块 8 DI 24V DC, 模块诊断; 包括总线模块, 接口模块 IO 6ES7194-4..00-0AA0 单独订货
|
建议同时购买:
6ES7142-4BF00-0AA0
SIMATIC DP, ET 200 PRO 的电子模块 8 DO 24V DC,0.5A 模块诊断; 包括总线模块, 接口模块 IO 6ES7194-4..00-0AA0 单独订货
6ES7154-4AB10-0AB0
SIMATIC DP,PROFINET 接口模块 IM 154-4 PN, High Feature,用于 ET 200 PRO, 集成开关, 包括终端模块, PN 中的连接模块 6ES7194-4A.00-0AA0 单独订货
|
数字量扩展模板允许另外的执行器和传感器通过集成式输入 / 输出,与ET 200pro连接。
提供有以下模块:
I/O 连接模块(必须单独订货):
传感器和执行器可通过常规 5 针 M12 连接器、3 针 M8 连接器或 12 针 M23 连接器进行连接。
对于数字量输入或输出模块,可将以下连接形式与 IO 接口模块结合使用:
Article number |
6ES7141-4BF00-0AA0 |
6ES7141-4BF00-0AB0 |
6ES7141-4BH00-0AA0 |
|
---|---|---|---|---|
ET200PRO, EM 8DI 24V DC |
ET200PRO, EM 8DI 24V DC HF |
ET200PRO, EM 16DI DC 24V |
||
Supply voltage |
|
|
|
|
Rated value (DC) |
24 V |
24 V |
24 V |
|
Reverse polarity protection |
Yes; Against destruction; encoder power supply outputs applied with reversed polarity |
Yes; against destruction; load increasing |
Yes; Against destruction; encoder power supply outputs applied with reversed polarity |
|
Input current |
|
|
|
|
from supply voltage 1L+, max. |
20 mA |
40 mA |
30 mA |
|
from backplane bus 3.3 V DC, max. |
20 mA |
20 mA |
20 mA |
|
Encoder supply |
|
|
|
|
Number of outputs |
8 |
8 |
8 |
|
Short-circuit protection |
Yes; per module, electronic |
Yes; per channel, electronic |
Yes; per module, electronic |
|
Output current |
|
|
|
|
|
1 A |
1 A |
1 A |
|
Power loss |
|
|
|
|
Power loss, typ. |
2.5 W |
2.5 W |
3 W |
|
Address area |
|
|
|
|
Occupied address area |
|
|
|
|
|
1 byte |
1 byte |
2 byte |
|
Digital bs |
|
|
|
|
Number of digital bs |
8 |
8 |
16 |
|
Input characteristic curve in accordance with IEC 61131, type 1 |
Yes |
No |
Yes |
|
Input characteristic curve in accordance with IEC 61131, type 2 |
No |
Yes |
||
Number of simultaneously controllable bs |
|
|
|
|
all mounting bs |
|
|
|
|
|
8 |
8 |
16 |
|
Input voltage |
|
|
|
|
|
24 V |
24 V |
24 V |
|
|
-3 to +5V |
-3 to +5V |
-3 to +5V |
|
|
13 to 30V |
+11 to +30V |
+11 to +30V |
|
Input current |
|
|
|
|
|
7 mA |
7 mA |
4 mA |
|
Input delay (for rated value of b voltage) |
|
|
|
|
for standard bs |
|
|
|
|
|
No |
Yes |
No |
|
|
1.2 ms |
0.5 ms; 0.5 ms/ 3ms/ 15 ms/ 20 ms |
1.2 ms |
|
|
4.8 ms |
20 ms |
4.8 ms |
|
|
1.2 ms |
0.5 ms; 0.5 ms/ 3ms/ 15 ms/ 20 ms |
0.7 ms |
|
|
4.8 ms |
20 ms |
3 ms |
|
Cable length |
|
|
|
|
|
30 m |
30 m |
30 m |
|
|
30 m |
30 m |
30 m |
|
Encoder |
|
|
|
|
Connectable encoders |
|
|
|
|
|
Yes |
Yes |
Yes |
|
|
1.5 mA |
1.5 mA |
1.5 mA |
|
Isochronous mode |
|
|
|
|
Isochronous operation (application synchronized up to terminal) |
No |
No |
No |
|
Interrupts/diagnostics/status inbation |
|
|
|
|
Diagnostic functions |
Yes |
Yes; channel by channel, beterizable |
Yes |
|
Alarms |
|
|
|
|
|
Yes |
Yes |
Yes |
|
Diagnostic messages |
|
|
|
|
|
Yes |
Yes |
Yes |
|
|
Yes; Monitoring, I < 0.3 mA |
|||
|
Yes; Sensor supply to M; module by module |
Yes |
Yes; Sensor supply to M; module by module |
|
Diagnostics indication LED |
|
|
|
|
|
Yes |
Yes |
Yes |
|
|
Yes; Per channel |
Yes; Per channel |
Yes; Per channel |
|
Parameter |
|
|
|
|
Diagnostics wire break |
channel by channel |
|||
Diagnostics short-circuit |
Sensor supply to M; module by module |
channel by channel |
||
Potential separation |
|
|
|
|
between backplane bus and all other circuit components |
Yes |
Yes |
Yes |
|
Potential separation digital bs |
|
|
|
|
|
No |
No |
No |
|
|
Yes |
Yes |
Yes |
|
Isolation |
|
|
|
|
Isolation tested with |
707 V DC (type test) |
707 V DC (type test) |
707 V DC (type test) |
|
Dimensions |
|
|
|
|
Width |
45 mm |
45 mm |
45 mm |
|
Height |
130 mm |
130 mm |
130 mm |
|
Depth |
35 mm |
35 mm; without terminal module |
35 mm |
|
Weights |
|
|
|
|
Weight, approx. |
140 g |
140 g |
140 g |
Article number |
6ES7142-4BD00-0AA0 |
6ES7142-4BD00-0AB0 |
6ES7142-4BF00-0AA0 |
|
---|---|---|---|---|
ET200PRO, EM 4DO 24V DC/2.0A |
ET200PRO, EM 4DO 24VDC/2.0A HF |
ET200PRO, EM 8DO DC24V/0.5A |
||
Supply voltage |
|
|
|
|
Load voltage 2L+ |
|
|
|
|
|
24 V |
24 V |
24 V |
|
|
Yes; per channel, electronic |
Yes; per channel, electronic |
Yes; per channel, electronic |
|
|
Yes; against destruction; load increasing |
Yes; against destruction; load increasing |
Yes; against destruction; load increasing |
|
Input current |
|
|
|
|
from load voltage 2L+ (without load), max. |
20 mA |
40 mA |
30 mA |
|
from backplane bus 3.3 V DC, max. |
20 mA |
30 mA |
30 mA |
|
Power loss |
|
|
|
|
Power loss, typ. |
2 W |
2.5 W |
2 W |
|
Address area |
|
|
|
|
Address space per module |
|
|
|
|
|
4 bit |
4 bit |
8 bit |
|
|
1 byte |
1 byte |
1 byte |
|
Digital outputs |
|
|
|
|
Number of digital outputs |
4 |
4 |
8 |
|
Short-circuit protection |
Yes |
Yes |
Yes |
|
|
2.8 A |
2.8 A |
0.7 A |
|
Limitation of inductive shutdown voltage to |
2L+ (-47 V) |
2L+ (-47 V) |
2L+ (-47 V) |
|
Controlling a digital b |
Yes |
Yes |
Yes; Isolation between 1L+ and 2L+ is no longer provided, as 1M and 2M are jumpered |
|
Switching capacity of the outputs |
|
|
|
|
|
10 W |
10 W |
5 W |
|
Load resistance range |
|
|
|
|
|
12 Ω |
12 Ω |
48 Ω |
|
|
4 kΩ |
4 kΩ |
4 kΩ |
|
Output voltage |
|
|
|
|
|
2L+ (-0,8 V) |
2L+ (-0,8 V) |
2L+ (-0,8 V) |
|
Output current |
|
|
|
|
|
2 A |
2 A |
0.5 A |
|
|
0.5 mA |
0.5 mA |
0.5 mA |
|
Parallel switching of two outputs |
|
|
|
|
|
No |
No |
No |
|
|
Yes |
Yes |
Yes |
|
Switching frequency |
|
|
|
|
|
100 Hz |
100 Hz |
100 Hz |
|
|
0.5 Hz |
0.5 Hz |
0.5 Hz |
|
|
1 Hz |
1 Hz |
1 Hz |
|
Total current of the outputs (per group) |
|
|
|
|
all mounting bs |
|
|
|
|
|
4 A |
4 A |
4 A |
|
Cable length |
|
|
|
|
|
30 m |
30 m |
30 m |
|
|
30 m |
30 m |
30 m |
|
Interrupts/diagnostics/status inbation |
|
|
|
|
Diagnostic functions |
Yes |
Yes |
Yes |
|
Substitute values connectable |
Yes |
|||
Alarms |
|
|
|
|
|
Yes |
Yes |
Yes |
|
Diagnostic messages |
|
|
|
|
|
Yes |
Yes |
Yes |
|
|
Yes |
|||
|
Yes; Short-circuit of outputs to ground; module by module |
Yes |
Yes; Short-circuit of outputs to ground; module by module |
|
Diagnostics indication LED |
|
|
|
|
|
Yes |
Yes |
Yes |
|
|
Yes |
Yes |
Yes |
|
|
Yes |
|||
Parameter |
|
|
|
|
Diagnostics wire break |
channel by channel |
|||
Diagnostics short-circuit |
channel by channel |
|||
Potential separation |
|
|
|
|
between backplane bus and all other circuit components |
Yes |
Yes |
Yes |
|
Potential separation digital outputs |
|
|
|
|
|
No |
No |
No |
|
|
Yes |
Yes |
Yes |
|
Isolation |
|
|
|
|
Isolation tested with |
707 V DC (type test) |
707 V DC (type test) |
707 V DC (type test) |
|
Standards, approvals, certificates |
|
|
|
|
Suitable for safety-oriented group deactivation |
Yes |
Yes |
Yes |
|
Highest safety class achievable in safety mode |
|
|
|
|
|
d |
d |
d |
|
|
2 |
2 |
2 |
|
Dimensions |
|
|
|
|
Width |
45 mm |
45 mm |
45 mm |
|
Height |
130 mm |
130 mm |
130 mm |
|
Depth |
35 mm |
35 mm; without terminal module |
35 mm |
|
Weights |
|
|
|
|
Weight, approx. |
140 g |
140 g |
140 g |
Article number |
6ES7143-4BF50-0AA0 |
6ES7143-4BF00-0AA0 |
|
---|---|---|---|
ET200PRO, EM 4DI / 4DO DC 24V, 0.5A |
ET200PRO, EM 4 DIO / 4 DO DC 24V, 0.5A |
||
Supply voltage |
|
|
|
Rated value (DC) |
24 V |
||
Reverse polarity protection |
Yes; Against destruction; encoder power supply outputs applied with reversed polarity |
||
Load voltage 2L+ |
|
|
|
|
24 V |
24 V |
|
|
Yes |
Yes |
|
|
Yes |
Yes; against destruction; load increasing |
|
Input current |
|
|
|
from supply voltage 1L+, max. |
20 mA |
||
from load voltage 2L+ (without load), max. |
20 mA |
20 mA |
|
from backplane bus 3.3 V DC, max. |
20 mA |
30 mA |
|
Encoder supply |
|
|
|
Number of outputs |
4 |
4 |
|
Short-circuit protection |
Yes; per module, electronic |
Yes; per module, electronic |
|
Output current |
|
|
|
|
1 A |
1 A |
|
Power loss |
|
|
|
Power loss, typ. |
2 W |
3 W |
|
Digital bs |
|
|
|
Number of digital bs |
4 |
4; 4 DIOs can be beterized |
|
Input characteristic curve in accordance with IEC 61131, type 3 |
Yes |
Yes |
|
Number of simultaneously controllable bs |
|
|
|
all mounting bs |
|
|
|
|
4 |
||
Input voltage |
|
|
|
|
24 V |
24 V |
|
|
-3 to +5V |
-3 to +5V |
|
|
+11 to +30V |
+11 to +30V |
|
Input current |
|
|
|
|
7 mA |
7 mA |
|
Input delay (for rated value of b voltage) |
|
|
|
for standard bs |
|
|
|
|
1.2 ms |
||
|
3 ms |
4.8 ms |
|
|
1.2 ms |
||
|
3 ms |
4.8 ms |
|
Cable length |
|
|
|
|
30 m |
30 m |
|
|
30 m |
30 m |
|
Digital outputs |
|
|
|
Number of digital outputs |
4 |
8; 4 DO fixed, 4 DIO beterizable |
|
|
4; 2 load groups for 4 outputs each |
||
Short-circuit protection |
Yes; per channel, electronic |
Yes; per channel, electronic |
|
|
0.7 A |
0.7 A |
|
Limitation of inductive shutdown voltage to |
Typ. (2L+) -47 V |
Typ. (L1+, L2+) -47 V |
|
Controlling a digital b |
Yes |
Yes |
|
Switching capacity of the outputs |
|
|
|
|
5 W |
5 W |
|
Load resistance range |
|
|
|
|
48 Ω |
48 Ω |
|
|
4 kΩ |
4 kΩ |
|
Output voltage |
|
|
|
|
2L+ (-0,8 V) |
||
Output current |
|
|
|
|
0.5 A |
0.5 A |
|
|
0.5 mA |
0.5 mA |
|
Parallel switching of two outputs |
|
|
|
|
No |
No |
|
|
Yes |
Yes |
|
Switching frequency |
|
|
|
|
100 Hz |
100 Hz |
|
|
0.5 Hz |
0.5 Hz |
|
|
1 Hz |
1 Hz |
|
Total current of the outputs (per group) |
|
|
|
all mounting bs |
|
|
|
|
2 A |
2 A |
|
Cable length |
|
|
|
|
30 m |
30 m |
|
|
30 m |
30 m |
|
Encoder |
|
|
|
Connectable encoders |
|
|
|
|
Yes |
Yes |
|
|
1.5 mA |
1.5 mA |
|
Interrupts/diagnostics/status inbation |
|
|
|
Diagnostic functions |
Yes |
Yes |
|
Alarms |
|
|
|
|
Yes |
Yes |
|
Diagnostic messages |
|
|
|
|
Yes |
Yes |
|
|
Yes; Short-circuit of outputs to ground; module by module |
Yes; Short-circuit of outputs to ground; module by module |
|
Diagnostics indication LED |
|
|
|
|
Yes |
||
|
Yes |
Yes |
|
|
Yes |
Yes |
|
Potential separation |
|
|
|
between backplane bus and all other circuit components |
Yes |
Yes |
|
Potential separation digital bs |
|
|
|
|
No |
No |
|
|
Yes |
Yes |
|
Potential separation digital outputs |
|
|
|
|
No |
||
|
Yes |
Yes |
|
Isolation |
|
|
|
Isolation tested with |
707 V DC (type test) |
707 V DC (type test) |
|
Standards, approvals, certificates |
|
|
|
Suitable for safety-oriented group deactivation |
Yes |
||
Highest safety class achievable in safety mode |
|
|
|
|
d |
||
|
2 |
||
Dimensions |
|
|
|
Width |
45 mm |
45 mm |
|
Height |
130 mm |
130 mm |
|
Depth |
35 mm |
35 mm |
|
Weights |
|
|
|
Weight, approx. |
140 g |
140 g |
表1显示了总线模块,模块还有DP/PA Link模块以及Y Link模块的可能组合。
总线模块 IM 157 |
模块 IM 157 | 模块 IM 153-2 | 配置/功能 | |||
---|---|---|---|---|---|---|
6ES7157-0AA81-0XA0 | 6ES7157-0AA82-0XA0 | 6ES7153-2BA81-0XB0 | 6ES7153-2BA82-0XB0 | 6ES7153-2BA70-0XB0 | ||
6ES7195-7HE80-0XA0 | 是1) | 是1) | 是1) | 是1) | 否 | 6ES7157-0AA81-0XA0 |
6ES7195-7HD80-0XA0 | 否 | 是 | 是 | 是 | 否 | 6ES7157-0AA82-0XA0 |
否 | 否 | 是 | 是 | 是 | 6ES7153-2BA81-0XA0 及更高 |
表1
1) 在使用旧的CP 443-5 时(文章编号: 6GK7443-5DX02-0XE0), 在自动化系统中执行 IM 157/IM 153-2 只能在总线模块6ES7-7HE80-0XA0以及配置6ES70AA81-0XA0结合时操作。
表2 展示的是总线模块,模块(PROFIBUS IM 153-2)和配置ET 200M的可能组合。
总线模块 | IM 153-2 | IM 153-2 HF | 配置/功能 | ||||
---|---|---|---|---|---|---|---|
6ES7153-2AA02-0XB0 | 6ES7153-2BA00-0XB0 | 6ES7153-2BA01-0XB0 | 6ES7153-2BA02-0XB0 | 6ES7153-2BA10-0XB0 | |||
6ES7195-7HA00-0XA0 | 是 | 是 | 是 | 是 | 是 | 6ES7153-2AA02-0XB0 | |
否 | 是 | 是 | 是 | 是 | 6ES7153-2BA00-0XB0 及更高 | ||
6ES7195-7HD00-0XA0 | 是 | 是 | 是 | 是 | 否 | 6ES7153-2AA02-0XB0 | |
6ES7195-7HD10-0XA0 | 否 | 是 | 是 | 是 | 是 | 6ES7153-2AA02-0XB0 | |
否 | 是 | 是 | 是 | 是 | 6ES7153-2BA00-0XB0 及更高 |
表 2
表3 展示的是总线模块,模块(PROFIBUS IM 153-2 FO)和配置ET 200M的可能组合。
总线模块 | IM 153-2 FO | IM 153-2 FO HF | 配置/功能 | |
---|---|---|---|---|
6ES7153-2AB00-0XB0 | 6ES7153-2AB01-0XB0 | 6ES7153-2BB00-0XB0 | ||
6ES7195-7HA00-0XA0 | 是 | 是 | 是 | 6ES7153-2AB00-0XB0 |
否 | 是 | 是 | 6ES7153-2AB01-0XB0 | |
否 | 否 | 是 | 6ES7153-2BB00-0XB0 | |
6ES7195-7HD00-0XA0 | 是 | 是 | 是 | 6ES7153-2AB00-0XB0 |
否 | 是 | 是 | 6ES7153-2AB01-0XB0 | |
6ES7195-7HD10-0XA0 | 否 | 否 | 是 | 6ES7153-2AB00-0XB0 |
否 | 否 | 是 | 6ES7153-2AB01-0XB0 | |
否 | 否 | 是 | 6ES7153-2BB00-0XB0 |
表 3
表 4 显示的是哪个总线模块可以使用接口模块PROFIBUS IM153-1。
总线模块 | IM 153-1 | |||||
---|---|---|---|---|---|---|
6ES7153-1AA00-0XB0 | 6ES7153-1AA01-0XB0 | 6ES7153-1AA02-0XB0 | 6ES7153-1AA03-0XB0 | 6ES7153-1AA82-0XB0 | 6ES7153-1AA83-0XB0 | |
6ES7195-7HA00-0XA0 | 是 | 是 | 是 | 是 | 是 | 是 |
6ES7195-7HD00-0XA0 | 否 | 否 | 否 | 否 | 否 | 否 |
6ES7195-7HD10-0XA0 | 否 | 否 | 否 | 否 | 否 | 否 |
表 4
表5显示的是哪个总线模块可以使用接口模块IM 153-4。
总线模块 | IM 153-4 PN | IM 153-4 PN HF | |
---|---|---|---|
6ES7153-4AA00-0XB0 | 6ES7153-4AA00-0XB0 | 6ES7153-4BA00-0XB0 | |
6ES7195-7HA00-0XA0 | 是 | 是 | 是 |
6ES7195-7HD00-0XA0 | 否 | 否 | 否 |
6ES7195-7HD10-0XA0 | 否 | 否 | 否 |
表 5
描述
“技术数据” 和下表给出的 SIMATIC S7 存储卡(SMC)的规范:
订货号
|
产品
|
最小删除/写操作次数 |
最小数据保持时间 (最后一次编程之后) |
---|---|---|---|
6ES7954-8LB01-0AA0 | SIMATIC Memory Card, 2 MB |
500,000 |
10 年1) |
6ES7954-8LC01-0AA0 | SIMATIC Memory Card, 4 MB | 500,000 |
10 年1) |
6ES7954-8LC02-0AA0 | SIMATIC Memory Card, 4 MB | 500,000 | 10 年1) |
6ES7954-8LE01-0AA0 | SIMATIC Memory Card, 12 MB | 500,000 | 10 年1) |
6ES7954-8LE02-0AA0 | SIMATIC Memory Card, 12 MB | 500,000 | 10 年1) |
6ES7954-8LF01-0AA0 | SIMATIC Memory Card, 24 MB | 500,000 | 10 年1) |
6ES7954-8LF02-0AA0 | SIMATIC Memory Card, 24 MB | 500,000 | 10 年1) |
6ES7954-8LL02-0AA0 | SIMATIC Memory Card, 256 MB | 200,000 | 10 年2) |
6ES7954-8LP01-0AA0 | SIMATIC Memory Card, 2 GB | 100,000 | 10 年5) |
6ES7954-8LP02-0AA0 | SIMATIC Memory Card, 2 GB | 60,000 | 10 年3) |
6ES7954-8LT02-0AA0 | SIMATIC Memory Card, 32 GB | 50,000 | 10 年4) |
6ES7954-8LT03-0AA0 | SIMATIC Memory Card, 32 GB | 100,000 | 10 年5) |
1)如果删除/写操作次数 <50,000 则为10 年(如果删除/写操作次数 > 450,000 则为1 年)
2)如果删除/写操作次数 < 20,000 则为10 年( 如果删除/写操作次数 > 180,000 则为1 年)
3)如果删除/写操作次数 < 6,000 则为10 年( 如果删除/写操作次数 > 54,000 则为1 年)
4)如果删除/写操作次数 < 5,000 则为10 年( 如果删除/写操作次数 > 45,000 则为1 年)
5)如果删除/写操作次数 < 10,000 则为10 年( 如果删除/写操作次数 > 90,000 则为1 年)
最大的删除和写操作重复次数的 10% 规则适用于所有的 SMC 卡。
例如,对于 32GB 的 SMC 卡 ( 6ES7 954-8LT03-0AA0 ),
如果删除/写操作小于 10,000 次,那么该存储卡的最小服务生命周期是 10 年。但是如果删除/写操作超过 90,000 次,那么该存储卡的服务生命周期最小只有 1 年。
计算 32 GB SMC存储卡 (6ES7 954-8LT03-0AA0) 的服务生命周期
以下说明了 32 GB 的西门子存储卡的可写容量。
计算 SMC 卡的写容量,如下:
存储卡大小
|
||||
可写容量 | = | ------------------------------------- | * | 删除/写操作的最小次数 |
内部元数据总计 |
|
|||
举例 32 GB SD 卡: | ||||
32,000,000,000 字节 | ||||
可写容量 | = | --------------------------------- | * | 100,000 |
100 | ||||
可写容量 | = | 32 TB |
下面计算 32 GB SMC 存储卡的服务生命周期:
实例 1
如果每秒将 160 个字节的数据块写入到该卡中,那么该卡的服务生命周期是:32 TB / 160 bytes/s = 200,000,000,000 秒 (理论上 6334 年,假设 1 年 = 365.24 天)。
实例 2
如果每秒将 160 KB 的数据记录 (csv) 写入到该卡中,那么该卡的服务生命周期是:32 TB / 160 KB/s = 200,000,000 秒 (理论上 6.34 年)。
注意:
这里忽略了诸如在微软Windows中编写和删除操作和下载项目的操作,因为这些操作不会像上述操作那样频繁发生。
当超过存储卡的最小服务生命周期的 80% 时,S7-1500 CPU 的诊断缓冲区会显示一条信息。另外,当达到存储卡的最小服务生命周期的 100% 时,MAINT 指示灯也会亮起。
如果 S7 - 1500 CPU 模块的固件版本小于 V2.0,下面的 SMC 卡不支持此功能:
32 GB (订货号 6ES7 954-8LT03-0AA0)
固件版本 V2.1和 更高的 S7-1500 CPU 模块可以使用 “getsmcinfo” 块。此块可以在定义的服务生命期超过时显示诊断条目。 该块提供访问用户程序中的下列信息:
在集约使用的情况下(例如配方和归档),可以评估 SMC 的服务生命周期信息,并在相应的时间作为维修计划的一部分,相应地更换它。
表中列出的块对 SMC 有读/写访问权:
Block | Name | Debion |
---|---|---|
FB | SET_TIMEZONE | 设置时区 |
SFC 84 | WRIT_DBL | 将数据写入到装载存储器的数据块中 |
SFC 84 | CREATE_DB | 创建数据块 |
SFC 95 | DELETE_DB | 删除数据块 |
SFB 140 | DataLogCreate | 创建数据记录 |
SFB 142 | DataLogWrite | 写入数据记录 |
SFB 143 | DataLogClear | 清空数据记录 |
SFB 144 | DataLogClose | 关闭数据记录 |
SFB 145 | DataLogDelete | 删除数据记录 |
SFB 147 | DataLogOpen | 打开数据记录 |
SFB 148 | DataLogNewFile | 新文件中的数据记录 |
SFB 1003 | RecipeExport | 导出配方 |
注意
如果循环调用表中列出的块,可以显著缩短 SMC 的使用寿命
固件版本为V1.0或更高的"TM Count 1x24V" 和 "TM PosInput 1" 模块可以在以下ET 200SP接口模块下使用:
工艺模块支持以下列出的操作模式:
注意
警告
该常问问题仅适用于 STEP 7 (TIA Portal) V13 以及更高版本,因为版本低于 V13 的STEP7 的工艺对象是无法使用的。