产品简介
崇安区  6SL3040-0JA00-0AA0
崇安区 6SL3040-0JA00-0AA0
产品价格:¥88
上架日期:2018-07-16 13:28:27
产地:德国
发货地:上海
供应数量:不限
最少起订:1件
浏览量:99
资料下载:暂无资料下载
其他下载:暂无相关下载
详细说明

    崇安区  6SL3040-0JA00-0AA0

    SINAMICS S110 控制单元 CU305 DP 带 PROFIBUS 接口 不带存储卡

    概述

    CU305 PN Control Unit

    The CU305 Control Unit for the communication and open-loop/closed-loop control functions of a SINAMICS S110 is combined with the PM240‑2 Power Module in blocksize bat (usable as of firmware V4.4 SP3) to create a powerful single drive.

    设计

    The CU305 Control Unit features the following connections and interfaces as standard:

    • Fieldbus interface
      • CU305 PN: 1 PROFINET interface with 2 ports (RJ45 sockets) with PROFIdrive V4 profile
      • CU305 DP: 1 PROFIBUS interface with PROFIdrive V4 profile
    • 1 DRIVE-CLiQ socket, used solely to connect a DRIVE-CLiQ motor or a Sensor Module
    • 1 onboard encoder buation for buating the following encoder signals
      • Incremental encoder TTL/HTL
      • SSI encoder without incremental signals
    • 1 PE/protective conductor connection
    • 1 connection for the electronics power supply via the 24 V DC power supply connector
    • 1 temperature sensor b (KTY84‑130 or PTC)
    • 3 beterizable, fail-safe digital bs (isolated), or alternatively 6 beterizable digital bs (isolated)
    • 5 beterizable digital bs (isolated)
    • 1 beterizable, fail-safe digital output (isolated), or alternatively 1 digital output (isolated)
    • 4 beterizable bidirectional digital bs/outputs
    • 1 analog b ± 10 V, resolution 12 bit + sign
    • 1 serial RS232 interface
    • 1 slot for the memory card on which the firmware, beters and licenses can be stored
    • 1 PM-IF interface for communication with the PM240‑2 Power Modules in blocksize bat (usable as of firmware V4.4 SP3)
    • 2 test sockets and one reference ground for commissioning support
    • 1 interface to the BOP20 Basic Operator Panel

    集成

    The CU305 Control Unit controls the PM240 2 Power Module in blocksize bat (usable as of firmware V4.4 SP3) via the PM-IF interface.

    A BOP20 Basic Operator Panel can also be snapped directly onto the CU305 for diagnostic purposes.

    DRIVE-CLiQ motors can be connected to the integrated DRIVE-CLiQ socket as well as Sensor Modules (SMC) to permit the operation of motors without a DRIVE-CLiQ interface.

    The status of the CU305 is indicated via multi-color LEDs.

    The CU305 can be operated optionally with memory card. The firmware and project data are stored on the memory card pluggable from below, so that the CU305 can be replaced without the support of software tools. This memory card can also be used to perb standard commissioning on multiple drives of identical type. The card is available as an empty memory card or containing the latest drive firmware version. The card also contains the safety license for the Extended Safety Functions. To use these Extended Safety Functions, a memory card containing the safety license must be permanently inserted.

    The CU305 and other connected components are commissioned and diagnosed with the STARTER commissioning tool.

    Connection example of CU305 Control Unit

    技术规范

    CU305 PN / CU305 DP Control Units

    PROFINET: 6SL3040-0JA01-0AA0

    PROFIBUS: 6SL3040-0JA00-0AA0

     

    Current requirement

    At 24 V DC, max.
    without taking account of digital outputs and DRIVE-CLiQ supply

    0.8 A for CU305 incl. 350 mA for HTL encoder + 0.5 A for PM240‑2 Power Module

    Conductor cross-section, max.

    2.5 mm2

    Fuse protection, max.

    20 A

    Digital bs

    in accordance with IEC 61131‑2 Type 1

    3 isolated fail-safe bs

    5 isolated digital bs

    • Voltage

    -3 ... +30 V

    • Low level (an open digital b is interpreted as "low")

    -3 ... +5 V

    • High level

    15 ... 30 V

    • Current consumption at 24 V DC, typ.

    6 mA

    • Delay time of digital bs 1), approx.

     

    • L → H

    15 μs

    • H → L

    55 μs

    • Delay time of high-speed digital bs 1), approx. 
      (high-speed digital bs can be used for b detection)

     

    • L → H

    5 μs

    • H → L

    5 μs

    • Conductor cross-section, max.

    1.5 mm2

    Digital outputs

    (continuously short-circuit-proof)

    1 fail-safe digital output

    4 bidirectional digital bs/digital outputs, not isolated

    • Voltage

    24 V DC

    • Load current per digital output 2), max.

    100 mA

    • Delay time 1), approx.

    150 μs

    • Conductor cross-section, max.

    1.5 mm2

    Analog b

    -10 ... +10 V
    Resolution 12 bits + sign

    • Internal resistance

    15 kΩ

    Encoder buation

    • Incremental encoder TTL/HTL
    • SSI encoder without incremental signals
    • Encoder supply

    24 V DC/0.35 A or 5 V DC/0.35 A

    • Input current range TTL/HTL

    2 ... 10 mA (typ. 5 mA)

    • Encoder frequency, max.

    500 kHz

    • SSI baud rate

    100 ... 250 kBaud
    depending on cable length

    • Resolution absolute b SSI

    30 bit

    • Cable length, max.

     

    • TTL encoder

    100 m (328 ft)

    (only bipolar signals permitted) 3)

    • HTL encoder

    100 m (328 ft) for unipolar signals

    300 m (984 ft) for bipolar signals 3)

    • SSI encoder

    100 m (328 ft)

    Power loss

    <20 W

    PE connection

    M5 screw

    Dimensions

     

    • Width

    73 mm (2.87 in)

    • Height

     

    • CU305 PN

    195 mm (7.68 in)

    • CU305 DP

    183.2 mm (7.21 in)

    • Depth

     

    • CU305 PN

    71 mm (2.80 in)

    • CU305 DP

    55 mm (2.17 in)

    Weight, approx.

    0.95 kg (2.09 lb)

    Certificate of suitability

    cULus