BEHLKE公司是高压电子开关领域的专业厂商。BEHLKE在全世界多个陆续建立了本土化的销售服务体系。目前,BEHLKE凭借其不断革新的技术,的产品性能,和良好的客户服务体系,使得BEHLKE在全球的高压电子开关市场上享有极高的声誉。BEHLKE是值得信赖的高压电子开关供应商。
焦生辉 手机:15037114264
电话:010-64714988-175
QQ:2853369891
邮箱:2853369891@qq.com/sales17@handelsen.cn
主页:www.handelsen.cn
汉达森微信号:handelsen
地址:北京市 朝阳区 广顺北大街北口222号 星源国际B座1707
Behlke产品分类
高压电子开关、高压发生器
Behlke主要应用:
需要产生高电压快速脉冲的场合,例如:快速脉冲群发生器,泡克耳斯盒驱动器,雷达调节器等
Behlke主要系列:
HTS全系列
德国Behlke HTS 60-100-SCR
德国Behlke HTS 60-200-SCR
德国Behlke HTS 120-100-SCR
德国Behlke HTS 40-1000-SCR
德国Behlke HTS 80-200-SCR
德国Behlke HTS 80-500-SCR
德国Behlke HTS 160-200-SCR
德国Behlke HTS 150-200-SCR
德国Behlke HTS 300-100-SCR
德国Behlke HTS 60-1000-SCR
北京汉达森公司以客户需求为导向,专业服务于工业领域的国内外设备及设备配件专业销售。BEHLKE集团是世界上的高压电子开关生产品牌,采用进口技术的BEHLKE系列产品品质优良,汉达森公司与BEHLKE厂家有着直接联系,省去中间费用,价格优惠。BEHLKE以的产品、技术来到中国,竭诚为您服务,欢迎来电垂询!
Switch Model [sorted by voltage] |
Debion / Comment ● Preferred stock type ○ Limited stock X Not for new development |
Max. Voltage[kV] |
Peak Current [A] |
Peak Power [MW] |
On-Resist. [Ω] |
On- Time [ns] |
Flange Housing Dimensions [mm3] |
Drawing (PDF) |
|
HTS 61-10-LC2 | ● | Standard DAP housing with internal control unit |
6
|
100
|
0.6 |
2.3
|
120…∞
|
103 x 70 x 35
|
request |
HTS 61-20-LC2 | ● | Standard DAP housing with internal control unit |
6
|
200
|
1.2 |
1.15
|
120…∞
|
103 x 70 x 35
|
request |
HTS 61-40-LC2 | ● | Flange housing. Internal control unit. |
6
|
400
|
2.4 |
0.65
|
120…∞
|
115 x 75 x 75
|
request |
HTS 61-80-LC2 | ● | Flange housing. Internal control unit. |
6
|
800
|
4.8 |
0.29
|
120…∞
|
175 x 75 x 75
|
request |
HTS 121-10-LC2 | ● | Standard DAP housing with internal control unit |
12
|
100
|
1.2 |
4.6
|
120…∞
|
103 x 70 x 35
|
request |
HTS 121-20-LC2 | ● | Standard DAP housing with internal control unit |
12
|
200
|
2.4 |
2.3
|
120…∞
|
103 x 70 x 35
|
request |
HTS 121-40-LC2 | ● | Flange housing. Internal control unit. |
12
|
400
|
4.8 |
1.65
|
120…∞
|
115 x 75 x 75
|
request |
HTS 121-80-LC2 | ● | Flange housing. Internal control unit. |
12
|
800
|
9.6 |
0.82
|
120…∞
|
175 x 100 x 75
|
request |
HTS 121-120-LC2 | ● | Flange housing. Int. or ext. control unit. High current terminals. I-FWDN integrated. |
12
|
1200
|
14.4 |
0.38
|
120…∞
|
240 x 150 x 80
|
request |
HTS 121-240-LC2 | ● | Flange housing. Int. or ext. control unit. High current terminals. I-FWDN integrated. |
12
|
2400
|
18.8 |
0.19
|
120…∞
|
240 x 150 x 150
|
request |
HTS 151-10-LC2 | ● | Flange housing. Internal or ext. control unit. HV pigtails, bus bars or connector bolts. |
15
|
100
|
1.5 |
6.08
|
120…∞
|
175 x 75 x 56
|
request |
HTS 151-20-LC2 | ● | Flange housing. Internal or ext. control unit. HV pigtails, bus bars or connector bolts. |
15
|
200
|
3 |
3.04
|
120…∞
|
175 x 75 x 56
|
request |
HTS 151-40-LC2 | ● | Flange housing. Internal or ext. control unit. HV pigtails, bus bars or connector bolts. |
15
|
400
|
6 |
1.52
|
120…∞
|
125 x 125 x 75
|
request |
HTS 151-80-LC2 | ● | Flange housing. Internal or ext. control unit. High current terminals. |
15
|
800
|
12 |
0.76
|
120…∞
|
175 x 125 x 75
|
request |
HTS 151-120-LC2 | ● | Flange housing. Internal or ext. control unit. High current terminals. |
15
|
1200
|
18 |
1.7
|
120…∞
|
240 x 125 x 80
|
request |
HTS 151-240-LC2 | ● | Flange housing. Internal or ext. control unit. High current terminals. |
15
|
2400
|
36 |
0.85
|
120…∞
|
240 x 125 x 150
|
request |
HTS 201-10-LC2 | ● | Flange housing. Internal or ext. control unit. HV pigtails, bus bars or connector bolts. |
20
|
100
|
2 |
7.8
|
150…∞
|
200 x 75 x 56
|
|
HTS 201-20-LC2 | ● | Flange housing. Internal or ext. control unit. HV pigtails, bus bars or connector bolts. |
20
|
200
|
4 |
3.9
|
150…∞
|
200 x 75 x 56
|
|
HTS 201-40-LC2 | ● | Flange housing. Internal or ext. control unit. HV pigtails, bus bars or connector bolts. |
20
|
400
|
8 |
1.9
|
150…∞
|
200 x 150 x 56
|
request |
HTS 201-80-LC2 | ● | Flange housing. Internal or ext. control unit. High current terminals. |
20
|
800
|
16 |
0.95
|
150…∞
|
200 x 150 x 80
|
request |
HTS 201-120-LC2 | ● | Flange housing. Internal or ext. control unit. High current terminals. |
20
|
1200
|
24 |
0.63
|
150…∞
|
252 x 175 x 80
|
request |
HTS 201-160-LC2 | ● | Flange housing. Internal or ext. control unit. High current terminals. |
20
|
1600
|
32 |
0.47
|
150…∞
|
312 x 175 x 80
|
request |
HTS 201-200-LC2 | ● | Flange housing. Internal or ext. control unit. High current terminals. |
20
|
2000
|
40 |
0.38
|
150…∞
|
372 x 175 x 80
|
request |
HTS 201-400-LC2 | ● | Flange housing. Internal or ext. control unit. High current terminals. |
20
|
4000
|
80 |
0.19
|
150…∞
|
372 x 175 x 150
|
request |
HTS 241-10-LC2 | ● | Flange housing. Internal or ext. control unit. HV pigtails, bus bars or connector bolts. |
24
|
100
|
2.4 |
9.2
|
200…∞
|
252 x 75 x 56
|
request |
HTS 241-20-LC2 | ● | Flange housing. Internal or ext. control unit. HV pigtails, bus bars or connector bolts. |
24
|
200
|
4.8 |
4.6
|
200…∞
|
252 x 75 x 56
|
request |
HTS 241-40-LC2 | ● | Flange housing. Internal or ext. control unit. HV pigtails, bus bars or connector bolts. |
24
|
400
|
9.6 |
2.3
|
200…∞
|
252 x 175 x 56
|
|
HTS 241-80-LC2 | ● | Flange housing. Internal or ext. control unit. High current terminals. |
24
|
800
|
19.2 |
1.15
|
200…∞
|
200 x 175 x 80
|
request |
HTS 241-120-LC2 | ● | Flange housing. Internal or ext. control unit. High current terminals. |
24
|
1200
|
28.8 |
0.76
|
200…∞
|
252 x 175 x 80
|
request |
HTS 241-160-LC2 | ● | Flange housing. Internal or ext. control unit. High current terminals. |
24
|
1600
|
38.4 |
0.57
|
200…∞
|
312 x 175 x 80
|
request |
HTS 241-200-LC2 | ● | Flange housing. Internal or ext. control unit. High current terminals. |
24
|
2000
|
48 |
0.46
|
200…∞
|
372 x 175 x 80
|
request |
HTS 241-400-LC2 | ● | Flange housing. Internal or ext. control unit. High current terminals. |
24
|
4000
|
96 |
0.23
|
200…∞
|
372 x 175 x 150
|
request |
HTS 301-10-LC2 | ● | Flange or tubular housing. Internal or ext. control unit. All HV connector options. |
30
|
100
|
3 |
11.4
|
200…∞
|
275 x 75 x 58
|
|
HTS 301-20-LC2 | ● | Flange or tubular housing. Internal or ext. control unit. All HV connector options. |
30
|
200
|
6 |
5.7
|
200…∞
|
275 x 75 x 58
|
|
HTS 301-40-LC2 | ● | Flange or tubular housing. Internal or ext. control unit. All HV connector options. |
30
|
400
|
12 |
2.9
|
200…∞
|
275 x 150 x 58
|
request |
HTS 301-80-LC2 | ● | Flange housing. Internal or ext. control unit. High current terminals. |
30
|
800
|
24 |
1.43
|
200…∞
|
225 x 225 x 80
|
request |
HTS 301-120-LC2 | ● | Flange housing. Internal or ext. control unit. High current terminals. |
30
|
1200
|
36 |
2.9
|
200…∞
|
252 x 225 x 80
|
request |
HTS 301-160-LC2 | ● | Flange housing. Internal or ext. control unit. High current terminals. |
30
|
1600
|
48 |
0.71
|
200…∞
|
312 x 225 x 80
|
request |
HTS 301-200-LC2 | ● | Flange housing. Internal or ext. control unit. High current terminals. |
30
|
2000
|
60 |
0.57
|
200…∞
|
372 x 225 x 80
|
request |
HTS 301-400-LC2 | ● | Flange housing. Internal or ext. control unit. High current terminals. |
30
|
4000
|
120 |
0.29
|
200…∞
|
372 x 225 x 150
|
request |
HTS 401-10-LC2 | ● | Flange or tubular housing. Internal or ext. control unit. All HV connector options. |
40
|
100
|
4 |
15.2
|
200…∞
|
350 x 75 x 58
|
|
HTS 401-20-LC2 | ● | Flange or tubular housing. Internal or ext. control unit. All HV connector options. |
40
|
200
|
8 |
7.1
|
200…∞
|
350 x 75 x 58
|
|
HTS 401-40-LC2 | ● | Flange or tubular housing. Internal or ext. control unit. All HV connector options. |
40
|
400
|
16 |
3.6
|
200…∞
|
350 x 150 x 58
|
request |
HTS 401-80-LC2 | ● | Flange housing. Internal or ext. control unit. High current terminals. |
40
|
800
|
32 |
1.8
|
200…∞
|
350 x 150 x 80
|
request |
HTS 401-120-LC2 | ● | Flange housing. Internal or ext. control unit. High current terminals. |
40
|
1200
|
48 |
1.27
|
200…∞
|
312 x 300 x 80
|
request |
HTS 401-160-LC2 | ● | Flange housing. Internal or ext. control unit. High current terminals. |
40
|
1600
|
64 |
0.9
|
200…∞
|
372 x 300 x 80
|
request |
HTS 401-200-LC2 | ● | Flange housing. Internal or ext. control unit. High current terminals. |
40
|
2000
|
80 |
0.71
|
200…∞
|
432 x 300 x 80
|
request |
HTS 401-400-LC2 | ● | Flange housing. Internal or ext. control unit. High current terminals. |
40
|
4000
|
160 |
0.36
|
200…∞
|
432 x 300 x 150
|
request |
HTS 501-10-LC2 | ● | Flange or tubular housing. Internal or ext. control unit. All HV connector options. |
50
|
100
|
5 |
19
|
250…∞
|
252 x 150 x 58
|
request |
HTS 501-20-LC2 | ● | Flange or tubular housing. Internal or ext. control unit. All HV connector options. |
50
|
200
|
10 |
8.5
|
250…∞
|
252 x 200 x 58
|
request |
HTS 501-40-LC2 | ● | Flange or tubular housing. Internal or ext. control unit. All HV connector options. |
50
|
400
|
20 |
4.25
|
250…∞
|
372 x 150 x 58
|
request |
HTS 501-80-LC2 | ● | Flange housing. Internal or ext. control unit. High current terminals. | 50 | 800 | 40 | 2.12 | 250…∞ |
372 x 300 x 58
|
request |
HTS 501-160-LC2 | ● | Flange housing. Internal or ext. control unit. High current terminals. | 50 | 1600 | 80 | 1.06 | 250…∞ |
372 x 300 x 90
|
request |
HTS 501-320-LC2 | ● | Flange housing. Internal or ext. control unit. High current terminals. | 50 | 3200 | 160 | 0.53 | 250…∞ |
372 x 300 x 160
|
request |
HTS 701-10-LC2 | ● | Flange housing with internal control unit or tubular housing with ext. control unit |
70
|
100
|
7 |
25
|
250…∞
|
312 x 150 x 58
|
|
HTS 701-20-LC2 | ● | Flange housing with internal control unit or tubular housing with ext. control unit |
70
|
200
|
14 |
12.5
|
250…∞
|
312 x 200 x 58
|
request |
HTS 701-40-LC2 | ● | Flange housing with internal control unit or tubular housing with ext. control unit | 70 |
400
|
28 |
6.25
|
250…∞
|
492 x 200 x 58
|
request |
HTS 701-80-LC2 | ● | Flange housing with internal control unit or tubular housing with ext. control unit | 70 |
800
|
56 |
3.2
|
250…∞
|
492 x 200 x 80
|
request |
HTS 701-120-LC2 | ● | Flange housing. Internal or ext. control unit. High current HV pigtails. | 70 |
1200
|
84 |
2.08
|
250…∞
|
492 x 300 x 58
|
request |
HTS 701-160-LC2 | ● | Flange housing. Internal or ext. control unit. High current HV pigtails. | 70 |
1600
|
112 |
1.6
|
250…∞
|
492 x 200 x 150
|
request |
HTS 901-10-LC2 | ● | Flange housing with internal control unit or tubular housing with ext. control unit |
90
|
100
|
9 |
38
|
250…∞
|
372 x 150 x 68
|
request |
HTS 901-20-LC2 | ● | Flange housing with internal control unit or tubular housing with ext. control unit | 90 |
200
|
18 |
19
|
250…∞
|
372 x 200 x 68
|
request |
HTS 901-40-LC2 | ● | Flange housing with internal control unit or tubular housing with ext. control unit | 90 |
400
|
36 |
8.5
|
250…∞
|
552 x 200 x 68
|
request |
HTS 901-80-LC2 | ● | Flange housing with internal control unit or tubular housing with ext. control unit | 90 |
800
|
72 |
4.25
|
250…∞
|
552 x 200 x 90
|
request |
HTS 901-120-LC2 | ● | Flange housing. Internal or ext. control unit. High current HV pigtails. | 90 |
1200
|
108 |
3.16
|
250…∞
|
552 x 250 x 90
|
request |
HTS 1001-10-LC2 | ● | Flange housing with internal control unit or tubular housing with ext. control unit |
100
|
100
|
10 |
40
|
250…∞
|
432 x 150 x 68
|
request |
HTS 1001-20-LC2 | ● | Flange housing with internal control unit or tubular housing with ext. control unit |
100
|
200
|
20 |
20
|
250…∞
|
432 x 200 x 68
|
request |
HTS 1001-40-LC2 | ● | Flange housing with internal control unit or tubular housing with ext. control unit |
100
|
400
|
40 |
10
|
250…∞
|
612 x 150 x 68
|
request |
HTS 1001-80-LC2 | ● | Flange housing with internal control unit or tubular housing with ext. control unit |
100
|
800
|
80 |
5
|
250…∞
|
612 x 200 x 90
|
request |
HTS 1001-120-LC2 | ● | Flange housing. Internal or ext. control unit. High current HV pigtails. |
100
|
1200
|
120 |
2.5
|
250…∞
|
612 x 250 x 90
|
request |
HTS 1201-10-LC2 | ● | Flange housing with internal control unit or tubular housing with ext. control unit |
120
|
100
|
12 |
42
|
250…∞
|
552 x 150 x 68
|
request |
HTS 1201-20-LC2 | ● | Flange housing with internal control unit or tubular housing with ext. control unit |
120
|
200
|
24 |
21
|
250…∞
|
552 x 200 x 68
|
request |
HTS 1201-40-LC2 | ● | Flange housing with internal control unit or tubular housing with ext. control unit |
120
|
400
|
48 |
21
|
250…∞
|
552 x 200 x 90
|
request |
HTS 1201-80-LC2 | ● | Flange housing with internal control unit or tubular housing with ext. control unit |
120
|
800
|
96 |
10.5
|
250…∞
|
552 x 250 x 90
|
request |
HTS 1401-10-LC2 | ● | Flange housing with internal control unit or tubular housing with ext. control unit | 140 |
100
|
14 |
52
|
250…∞
|
672 x 150 x 68
|
request |
HTS 1401-20-LC2 | ● | Flange housing with internal control unit or tubular housing with ext. control unit | 140 |
200
|
28 |
26
|
250…∞
|
672 x 200 x 68
|
request |
HTS 1401-40-LC2 | ● | Flange housing with internal control unit or tubular housing with ext. control unit | 140 |
400
|
56 |
13
|
250…∞
|
672 x 250 x 90
|
request |
HTS 1401-80-LC2 | ● | Flange housing with internal control unit or tubular housing with ext. control unit | 140 |
800
|
112 |
6.5
|
250…∞
|
672 x 300 x 90
|
request |
LC switches. Prefered in high frequency applications with low capacitive load. Please scroll down for the options list. | |||||||||
Switch Model [sorted byvoltage] |
Debion / Comment |
Max. Voltage[kV] |
Peak Current |
Peak Power [MW] |
On-Resist. |
On- Time |
Housing Dimensions |
Drawing (PDF) |
|
HTS 31-12-LC | ● |
3
|
120
|
0.36 |
1.25
|
60…∞
|
89 x 64 x 27
|
request | |
HTS 41-12-LC | ● |
4.5
|
120
|
0.54 |
2.5
|
60…∞
|
112 x 64 x 27
|
request | |
HTS 61-06-LC | ● |
6
|
60
|
0.36 |
5
|
60…∞
|
89 x 64 x 27
|
request | |
HTS 81-12-LC | ○ |
8
|
120
|
0.96 |
3.75
|
100…∞
|
200 x 70 x 27
|
request | |
HTS 91-06-LC | ● |
9
|
60
|
0.54 |
10
|
60…∞
|
112 x 64 x 27
|
request | |
HTS 91-12-LC | ● |
9
|
120
|
1.08 |
3.75
|
100…∞
|
200 x 70 x 27
|
request | |
HTS 111-03-LC | ● |
11
|
30
|
0.33 |
24
|
60…∞
|
89 x 64 x 27
|
request | |
HTS 121-03-LC | ○ |
12
|
30
|
0.36 |
24
|
60…∞
|
89 x 64 x 27
|
request | |
HTS 161-03-LC | ● |
16
|
30
|
0.48 |
36
|
60…∞
|
112 x 64 x 27
|
request | |
HTS 161-06-LC | ○ |
16
|
60
|
0.96 |
15
|
100…∞
|
200 x 70 x 27
|
request | |
HTS 161-12-LC | ○ |
16
|
120
|
1.92 |
7.5
|
150…∞
|
263 x 70 x 35
|
request | |
HTS 181-03-LC | ○ |
18
|
30
|
0.54 |
36
|
60…∞
|
112 x 64 x 27
|
request | |
HTS 181-06-LC | ● |
18
|
60
|
1.08 |
15
|
100…∞
|
200 x 70 x 27
|
request | |
HTS 181-12-LC | ● |
18
|
120
|
2.16 |
7.5
|
150…∞
|
263 x 70 x 35
|
request | |
HTS 331-06-LC | ○ |
33
|
60
|
1.98 |
30
|
150…∞
|
263 x 70 x 35
|
request | |
HTS 331-03-LC | ● |
33
|
30
|
0.99 |
72
|
100…∞
|
200 x 70 x 35
|
request | |
HTS 361-03-LC | ○ |
36
|
30
|
1.08 |
72
|
100…∞
|
200 x 70 x 35
|
request | |
HTS 361-06-LC | ● |
36
|
60
|
2.16 |
30
|
150…∞
|
263 x 70 x 35
|
request | |
Outdated switch models. Switches are available, but not recommended for new development: | |||||||||
HTS 501-03-LC | X | Use HTS 501-10-LC2 for new development |
50
|
30
|
1.5 |
86
|
150…∞
|
260 x 70 x 35
|
request |
HTS 651-03-LC | X | Use HTS 701-10-LC2 for new development |
65
|
30
|
1.95 |
144
|
150…∞
|
300 x 70 x 35
|
request |
HTS 721-03-LC | X | Use HTS 701-10-LC2 for new development |
72
|
30
|
2.16 |
144
|
150…∞
|
300 x 70 x 35
|
request |
Options (1) |
|
|
|
B-CON | Beginner's Configuration: The standard switch is equipped with various options to simplify first time experiments for users which are inexperienced with high voltage and high frequency circuit design. The beginner's configuration includes option FH and PT-HV for easy wiring and attachment without printed circuit boards, as well as option LS-C, LP and S-TT for an uncritical EMC behavior. Inexperienced users should also consider the combination with option I-PC or PC to avoid possible difficulties from the high voltage wiring and / or high frequency noise behavior. (2) |
HFB | High Frequency Burst: Improved burst capability of driver by means of external buffer capacitors. Recommended if more than 10 pulses with less than 10 μs spacing are generated. |
HFS |
High Frequency Switching: External supply of auxiliary driver voltage (50-350 VDC according to type). Necessary if the specified “Maximum Operating Frequency” shall be exceeded. (2) |
LP |
Low Pass: Low pass filter at the control b. Propagation delay time will be increased by ~50 ns. Jitter + 500 ps. Improved noise immunity and less critical wiring in high speed applications. (3) |
FAST |
Faster Switching Times (-30 to -40%) due to increased driver power. Minimum on-times will be reduced by about 40 to 50%. For selected high current switches only. Please consult factory. (2) |
MIN-ON |
Minimum On-Time: Individually increased Minimum On-Time to ensure a minimum on duration indepently of control signal. For safety relevant circuits. |
MIN-OFF |
Minimum Off-Time: Individually increased Minimum Off-Time to ensure a minimum off duration indepently of control signal. For safety relevant circuits. |
S-TT |
Soft Transition Time: ”Turn-On Rise Time” & “Turn-Off Rise Time” increased by ~20%. Simplified EMC design and less critical wiring if the shortest possible edge steepness is not required. (3) |
LL |
Low Leakage Current: Off-state current reduced to less than 10% of the specified value. Not available in connection with the cooling fin options and for switches of the UF series. |
LN |
Low Noise: Internal power driver modified for zero noise emission for a specific period of time. Relevant in conjunction with sensitive detector amplifiers (e.g. SEV/MCP applications) only. (2) |
ISO-25 |
25 kV Isolation: Isolation Voltage increased to 25 kVDC. Housing dimensions may change for some models. |
ISO-40 |
40 kV Isolation: Isolation Voltage increased to 40 kVDC. Housing dimensions may change for some models. Only in connection with option PT-HV. |
ISO-80 |
80 kV Isolation: Isolation Voltage increased to 80 kVDC. Housing dimensions may change for some models. Only in connection with option PT-HV. |
ISO-120 |
120 kV Isolation: Isolation Voltage increased to 120 kVDC. Housing dimensions may change for some models. Only in connection with option PT-HV. |
ISO-200 |
200 kV Isolation: Isolation Voltage increased to 200 kVDC. Housing dimensions may change for some models. Only in connection with option PT-HV. |
I-PC |
Integrated Part Components: Integration of small part components according to customer’s specifications (e.g. buffer capacitors, snubbers, damping resistors, diodes, opto couplers). (2) |
I-FWD |
Integrated Free-Wheeling Diode: Built-in parallel diode with short recovery time. In connection with inductive load only. |
I-FWDN |
Integrated Free-Wheeling Diode Network: Built-in parallel diode plus serial blocking diode with short recovery time. In connection with inductive load only. |
LS-C |
LEMO socket for Control Connection. Input ipedance 100Ω. An assenbled bage cable (1m/3ft) with two plugs plus one additional socket is included in supply. Improved noise immunity. (3) |
PT-C |
Pigtail for Control Connection: Flexible leads (l=75 mm) with PCB connector. This option is only relevant for switching modules with pins. Recommended for modules with options CF & GCF. |
PT-HV |
Pigtails for HV Connection: Flexible leads with cable lugs. For increased creepage. PT-HV is standard for all types with >25 kV switching voltage. Not recommended in extremely fast circuits. |
ST-HV |
Screw Terminals for HV Connection: Threaded inserts at the bottom of module (if not standard). For PCB design. Operation above 25 kV requires liquid insulation (Galden®/Oil) or potting. |
SEP-C | Separated Control Unit. Control unit with LED indicators in a separate housing (dim. 79x38x17 mm). Linkage cable (<1m) with plug. Control unit with soldering pins or pigtails. |
FOI-I | Fibre Optics Input / Inhibit: Additional optical inhibit b to turn-off the switch by using the inhibit b with a fibre-optical signal (only in combination with option SEP-C) (2) |
FOI-C | Fibre Optics Input / Control: Additional optical control b to trigger the switch with a fibre-optical signal (only in combination with option SEP-C) (2) |
FOO-F | Fibre Optical Output / Fault: Additional optical output to read-out the failure condition with a fibre-optical signal (only in combination with option SEP-C) (2) |
UL94 |
Flame Retardant Casting Resin: Casting resin according to UL-94-VO. Minimum order quantity required. (2) |
FH | Flange Housing: Plastic flange housing for isolated attachment on conductive surfaces. Ideal if the switch is not intended for printed circuit boards. Option PT-HV is suggested. |
TH |
Tubular Housing: Tubular instead of rectangular housing. Adaption to specific ambient conditions or in case of difficult assembly situations. (2) |
FC |
Flat Case: Height of standard plastic housings reduced to 19 mm or less. Not in combination with cooling options CF, GCF and DLC. |
ITC |
Increased Thermal Conductivity: Special moulding process to increase the thermal conductivity of the module. Pd(max) will be increased by approx. 20-30%. (2) |
CF |
Copper Cooling Fins d = 0.5 mm: Fin height 35 mm. Nickel plated. For air cooling with forced or natural convection as well as for liquid cooling with non-conductive coolants. |
CF-1 |
Copper Cooling Fins d = 1 mm: Fin thickness 1.0 mm instead of 0.5 mm. The Max. Power Dissipation Pd(max) will be increased by ~80 %. For air or liquid cooling (e.g. Galden® or oil). |
CF-X2 |
Copper Cooling Fins "XL": Fin area enlarged by factor 2. Recommended for natural air convection. No significant cooling power improvement in connection with forced air or liquid cooling. |
CF-X3 |
Copper Cooling Fins "XXL": Fin area enlarged by factor 3. Recommended for natural air convection. No significant cooling power improvement in connection with forced air or liquid cooling. |
CF-CS |
Copper Cooling Fins with customized shape: Individual shape to meet specific OEM requirements. (2) Can be combined with options CF-1, CF-D and CF-S for increased cooling power. |
CF-LC |
Copper Cooling Fins for liquid cooling: Double fins, nickel plated copper, height 20 mm. For the immersion in oil tanks etc. Forced convection recommended. Combinable with opt. CF-S. |
CF-D |
Double Copper Cooling Fins: Approx. more cooling power, approx. 2mm spacing between fins, forced convection recommended. Combinable with opt. CF-S, CF-X2, CF-X3 and CF-CS. |
CF-S |
Copper Cooling Fins: Semiconductors soldered on fins. Approx. 30% to more cooling power (type depending). Combinable with options CF-D, CF-X2, CF-X3 and CF-CS. |
CF-GRA |
Non-isolated Cooling Fins made of graphite: Very light weight compared to copper at similar heat transfer, but reduced heat capacity. 0.5 or 1 mm thickness, height 35 mm. |
CF-CER |
Isolated Cooling Fins made of ceramics: Heat transfer properties similar to alumina. Forced convection recommended due to 2 mm spacing between fins. Height 35 mm. |
CCS |
Ceramic Cooling Surface: Top side of switching module made of ceramics. Heat transfer properties similar to alumina. Max. 20 kVDC isolation. Forced convection recommended. |
CCF |
Ceramic Cooling Flange: Bottom side of switching module made of a plano grinded ceramic plate. Integrated bl frame for unib and safe contact pressure. Max. 40 kVDC isolation. |
C-DR |
Cooling for Driver: Extra cooling for the driver and control electronics. Recommended in combination with option HFS at higher switching frequencies. (2) |
GCF |
Grounded Cooling Flange: Nickel-plated copper flange for medium power. Max. isolation voltage 40kV. Increased coupling capacitance CC. |
GCF-X2 |
Grounded Cooling Flange, Max. Continuous Power Dissipation increased by x2: Thermal resistance “Switch to Flange” reduced for twice the power capability. (2) |
ILC |
Indirect Liquid Cooling: Liquid cooling for all kind of conductive coolants incl. water. Internal heat exchanger made of ceramics. For medium power dissipation. |
DLC |
Direct Liquid Cooling: Internal cooling channels arround the power semiconductors. The most efficient cooling for high frequency applications. Non-conductive coolants only. |
HI-REL |
High Reliability / MIL Versions: Available on request. (2) |
|
|
(1) New option code: Data sheets may differ from this coding system (especially older ones) and do not indicate all possible options as per above table. (2) Please consult factory for detailed inbation. |
|
|
|