产品简介
961-085-000  961-086-000 MARSH BELLORFAM
961-085-000 961-086-000 MARSH BELLORFAM
产品价格:¥1
上架日期:2011-06-25 10:59:12
产地:
发货地:上海
供应数量:不限
最少起订:1个
浏览量:481
资料下载:暂无资料下载
其他下载:暂无相关下载
详细说明
     
    上海冠佑电气自动化有限公司随时欢迎您的来电咨询,低价现货供应 。
    电话:021-60483978  13916770581
    传真:021-34689102  联系人:陈尉
    商务QQ:1305857511  邮箱:2265736@163.com
    网址:www.gyautomation.com
    MARSH BELLORFAM(马士贝罗浮) 电气转换器 一级代理
    Type 1000
     
    Type 1000 I/P & E/P Transducers
    • Low Cost
    • Built-in Volume Booster
    • Small Size
    • Field Reversible
    • Low Air consumption
    • Mounts at Any Angle
    • Convenient External Span & Zero Adjusts
      (Except for Explosion Proof Models)
    • Light Weight
    • Wide Supply Pressure Range
    • Low Supply Pressure Sensitivity
    Product Detail:
    The Type 1000 Transducer is an electro-pneumatic device that reduces a supply pressure to a regulated output pressure directly proportional to an electrical b signal. The Type 1000 accepts a wide range of supply pressures, ranging from a minimum of 3 psig (0.2 BAR) above the maximum output up to 100 psig (6.9 BAR). An integral pneumatic volume booster is included in the design to provide high flow capacity (up to 12 SCFM/339 slpm). Model selections include general purpose, NEMA 4X Type, extended range, high relief, intrinsically safe, and explosion proof.
    Part Numbers:
    T-1000 General Purpose ordering inbation:
    Input
    Output*
    Part Number
    Impedance
    (nominal)
    psig
    BAR
    4-20mA
    3-9
    0.2-0.6
    961-072-000
    90Ω
    9-15
    0.6-1.0
    961-073-000
    90Ω
    3-15
    0.2-1.0
    961-070-000
    180Ω
    3-27
    0.2-1.9
    961-074-000
    220Ω
    6-30
    0.4-2.1
    961-075-000
    220Ω
    1-17
    0.07-1.2
    961-116-000
    250Ω
    3-15
    0.2-1.0
    961-089-000
    180Ω
    10-50mA
    3-15
    0.2-1.0
    961-076-000
    70Ω
    3-27
    0.2-1.9
    961-077-000
    85Ω
    6-30
    0.4-2.1
    961-078-000
    85Ω
     
    ============
     
    0-5V
    3-15
    0.2-1.0
    961-079-000
    615Ω
    3-27
    0.2-1.9
    961-080-000
    530Ω
    6-30
    0.4-2.1
    961-081-000
    530Ω
    1-9V
    3-15
    0.2-1.0
    961-085-000
    985Ω
    3-27
    0.2-1.9
    961-086-000
    840Ω
    6-30
    0.4-2.1
    961-087-000
    840Ω
    NOTE: For NEMA4X, add 004 suffix.
    T-1000 extended range ordering inbation:
    Input
    Output*
    Part Number
    Impedance
    (nominal)
    psig
    BAR
    0-60mA
    2-120
    0.1-8.3
    961-107-000
    220Ω
    4-20mA
    3-120
    0.2-8.3
    961-111-000
    260Ω
    2-60
    0.1-4.1
    961-117-000
    225Ω
    0-10V
    3-120
    0.2-8.3
    961-112-000
    805Ω
    0-5V
    2-60
    0.1-4.1
    961-118-000
    500Ω
    T-1000 HIGH RELIEF ordering inbation:
    Input
    Output*
    Part Number
    Impedance
    (nominal)
    psig
    BAR
    4-20mA
    3-9
    0.2-0.6
    961-130-000
    90Ω
    9-15
    0.6-1.0
    961-131-000
    90Ω
    3-15
    0.2-1.0
    961-132-000
    180Ω
    3-27
    0.2-1.9
    961-133-000
    220Ω
    6-30
    0.4-2.1
    961-134-000
    220Ω
    3-15
    0.2-1.0
    961-135-000
    180Ω
    1-17
    0.07-1.2
    961-136-000
    250Ω
    10-50mA
    3-15
    0.2-1.0
    961-137-000
    70Ω
    3-27
    0.2-1.9
    961-138-000
    85Ω
    6-30
    0.4-2.1
    961-139-000
    85Ω
    * For output pressures less than 3 psi (0.2 BAR) or greater than 30 psi (21 BAR), the Type 1000 transducer can be coupled to Bellofram Type 75 pneumatic relay. Consult Applications Engineers for further inbation.
    ** NEMA 4 type enclosure option available on all b/output ranges. This option is separate from explosion proof, NEMA 4 units.
     
    Type 1000 Explosion Proof
    Input
    Output*
    Part Number
    Impedance (nominal)
    Agency Approvals
    (see notes)
    psig
    BAR
    4-20mA
    3-15
    0.2-1.0
    961-098-000
    180Ω
    Explosion-Proof, Factory Mutual1
    3-15
    0.2-1.0
    961-098-100
    180Ω
    CSA Explosion Proof
    1-9v
    3-15
    20-100
    961-142-000
    985Ω
    Explosion Proof Factory Mutual1
    Type 1000 Intrinsically Safe
    4-20mA
    3-15
    0.2-1.0
    961-099-000
    180Ω
    Intrinsically Safe, Factory Mutual3,4
    3-27
    0.2-1.9
    961-100-000
    220Ω
    Intrinsically Safe, Factory Mutual3,4
    3-15
    0.2-1.0
    961-105-000
    180Ω
    Intrinsically Safe, CSA5
    3-27
    0.2-1.9
    961-106-000
    220Ω
    Intrinsically Safe, CSA5
    6-30
    0.4-2.1
    961-101-000
    220Ω
    Intrinsically Safe, Factory Mutual3,4
    15-3
    1.0-0.2
    961-175-000
    180Ω
    Intrinsically Safe, Factory Mutual3,4
    27-3
    1.9-0.2
    961-176-000
    220Ω
    Intrinsically Safe, Factory Mutual3,4
    30-6
    2.1-0.4
    961-177-000
    220Ω
    Intrinsically Safe, Factory Mutual3,4
    *For output pressures less than 3 psi or greater than 30 psi the Type 1000 transducer can be coupled to Bellofram Type 75 pneumatic relay.  Consult application engineers for further inbation.
    Agency Approval Notes:
    1. The Type 1000 Explosion-Proof Transducer has been bted, tested and approved by Factory Mutual Research for use in hazardous bs for Class I, Division 1, Group D, Class II, Division 1, Groups E, F & G and Class III requirements. It also has been approved to meet NEMA 4 Outdoor requirements.
    2. Canadian Standards Association certified for hazardous bs: Class I, Group D, Class II, Groups E, F and G, Class III, CSA Enc. 4.
    3. Factory Mutual Research Approved as intrinsically Safe for Class I, II, III, Division 1, Groups A, B, C, D, E, G when installed in accordance with interconnection diagram No. 541-000-012 and with the proper energy limiting barriers.
    4. Factory Mutual Research Approved as nonincendive for Class I, Division 2, Groups A, B, C, D, and suitable for Class II and III, Division 2, Group G. Barriers are not required for nonincendive rating.
    5. Canadian Standards Association certified as intrinsically safe when connected through certified diode safety barriers in accordance with Bellofram Installation Instruction 541-000-012.
    Explosion proof, intrinsically safe, and non-incendive ratings are not affected by recalibrating for split range or reverse acting applications.
    The Bellofram T-1000 Transducers were tested and found to comply with Electromagnetic compatibility Directive effective January 1, 1996. The relevant EMC specifications tested were the following: EN 50081-1 (1992) and EN 50082-1 (1992). A Technical Construction File, Serial #107 was written and Certificate of Conbity issued by a Competent Body.
    Options:
    Option
    Part Number/Last 3 digits
    Explosion Proof Mounting Kit
    971-079-000
    Explosion Proof Panel Mounting Kit
    971-078-000
    DIN Rail Kit
    010-115-000
    Hirschman Connector Kit (3-prong)
    971-126-000
    Filter Kit, Coalescing, 0.1 micron
    010-140-000
    Filter Element Kit
    (for coalescing filter, package of 10)
    010-141-000
    Output Gauges–Option “8”
    last 3 digits become - 008
    Dielectric Strength Testing Option “12”
    last 3 digits become - 012
    NEMA 4X Type Enclosure Option: Option “4”
    last 3 digits become - 004**
    ** NEMA 4 type enclosure option available on all b/output ranges. This option is separate from explosion proof, NEMA 4 units.
     